Specifications:
1) Rated voltage: 220V / single phase
2) Power range: 0.2 ~ 1.5kW
3) Output frequency: 1.0 ~ 400Hz
Features:
1) Static vector inverter adopting Dual-core CPU.
2) Frequency control mode of main/auxiliary frequency of overlapping.
3) Automatic voltage regulate function (AVR)
4) Analog frequency setting can accept 0 ~ 10V DC 4 ~ 20mA
5) Multifarious stop methods(off stop, stop for AVI zero)
6) Multi-display: Voltage, current, preset frequency and practical frequency, rotation value
7) Built-in PLC enables 16-level speed program running
PRODUCT ADVANTANGE
- Many machine lines and output is 10000set /month
- Customized specification is accepted.
- implement strict quality testing and control procedure to make superior quality.
- Delivery: 10-20 days (urgent 5-10 days)
- Certification: ISO 9001, ISO14001, OHSAS18001 & CE
COMPANY ADVANTAGE
- Qualified inverter supplier for FUJI Electric (Japan)
- 10 years OEM/ODM Experience
- Manufacture in this field for almost 20 years experience.
- Reasonable price and punctual delivery time
- 70 R & D personnel have many years experience
- Received the National Invention Award
Major Customers
- FUJI Electric
- Jeltron System PVT
- Senterno Sas
- Sinar Surya
- Electric Otomyson
Specification
Input Voltage Level |
220V |
Model S800-2S*** |
0.2G |
0.4G |
0.75G |
1.5G |
Applicable Motor Power(kw) |
0.2 |
0.4 |
0.75 |
1.5 |
Rated output capacity(Kva) |
0.6 |
1.0 |
1.6 |
2.9 |
Rated output current(A) |
1.6 |
2.5 |
4.2 |
7.0 |
Maximum output voltage(v) |
SINGLE-PHASE CORRESPONDING INPUT VOLTAGE |
Range of output frequency(Hz) |
1.0~400 Hz |
Rated input current(A) |
4.9/2.4 |
6.5/3.0 |
9.7/5.1 |
15.7/9 |
Admissible variation range |
Single-phase power supply 200-240V 50/60Hz |
of input voltage |
Variation range of power |
+-5% |
supply frequency |
Control mode |
V/F& SVPWM spatial vector modulation |
(carrier 2kHz-12kHz) |
Resolution of output frequency |
0.1 Hz |
Torque characteristic |
Torque and speed drop compensation function. |
trigger torque can be up to 150% in 3 Hz |
Overload toleration |
60 seconds under 150%of Rated output current |
Accelerating and decelerating time |
0.1~600seconds(can be set independently) |
V/F curve |
Randam V/F curve setting |
Action adjustment to avoid losing speed |
Set by percent of Rated current, 20%~200% |
Protective Function |
Over-voltage, over-current, low-voltage, overl |
oad limits, electronic thermocouple, overheat, |
self-check, ground protection, abnormal port |
Type of Cooling |
Air-blast cooling |
Using location |
Lower than 1000m, indoor(keep from corrosive |
gases, liquids and dust) |
Environment temperature |
-10~40(no dewing and icing) |
Storage temperature |
-20~60 |
Humidity |
Below 90%RH(no dewing) |
Vibration |
9.80665m/s2 below 20Hz(1G) 5.88m/s2 below |
20~50Hz(0.6G) |