• Mini Frequency Inverter for General Purpose (S800)
  • Mini Frequency Inverter for General Purpose (S800)
  • Mini Frequency Inverter for General Purpose (S800)

Mini Frequency Inverter for General Purpose (S800)

Application: High-performance Transducer, General Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Current
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
S800
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Simple Type
Brand
Sanch
Color
White
Transport Package
Polyfoam Packing First,Then Standard Export Carton
Trademark
Sanch
Origin
China
Production Capacity
50000 PCS /Year

Product Description

Specifications:
1) Rated voltage: 220V / single phase
2) Power range: 0.2 ~ 1.5kW
3) Output frequency: 1.0 ~ 400Hz
Input Voltage Level 220V
Model S8000-2s*** 0.2G 0.4G 0.75G 1.5G
Applicable Motor Power(kw) 0.2 0.4 0.75 1.5
Rated output capacity(Kva) 0.6 1.0 1.6 2.9
Rated output current(A) 1.6 2.5 4.2 7.0
Maximum output voltage(v) SINGLE-PHASE CORRESPONDING INPUT VOLTAGE
Range of output frequency(Hz) 1.0~400 Hz
Rated input current(A) 4.9/2.4 6.5/3.0 9.7/5.1 15.7/9
Admissible variation range Single-phase power supply 200-240V 50/60Hz
  of input voltage
Variation range of power +-5%
supply frequency
Control mode V/F& SVPWM spatial vector modulation
(carrier 2kHz-12kHz)
Resolution of output frequency 0.1 Hz
Torque characteristic Torque and speed drop compensation function.
trigger torque can be up to 150% in 3 Hz
Overload toleration 60 seconds under 150%of Rated output current
Accelerating and decelerating time 0.1~600seconds(can be set independently)
V/F curve Randam V/F curve setting
Action adjustment to avoid losing speed     Set by percent of Rated current, 20%~200%
Protective Function Over-voltage, over-current, low-voltage, overl
oad limits, electronic thermocouple, overheat,
self-check, ground protection, abnormal port
Type of Cooling Air-blast cooling
Using location Lower than 1000m, indoor(keep from corrosive
gases, liquids and dust)
Environment temperature -10~40(no dewing and icing)
Storage temperature -20~60
Humidity Below 90%RH(no dewing)
Vibration 9.80665m/s2 below 20Hz(1G) 5.88m/s2 below
20~50Hz(0.6G)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
Registered Capital
73901.09 USD
Management System Certification
ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001