Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Customization:

Contact Supplier

Gold Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
S2800
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
Brand
Machtric
Product Name
AC-DC-AC Motor Speed Controller
Control Mehtod
V/F;Vector Control Wihtout Pg
Voltage Range
330-440V
Power Range
7.5-110kw
Output Frequency Range
0.1-600Hz
Output Current
2.5A-210A
Protection
IP20
Certificate
Ce;ISO9001
PWM Carrier Frequency
Adjust From 0.5-15kHz
Features
Energy Saving;Eco-Friendly
Transport Package
Standard Export Packaging
Specification
depend
Trademark
Machtric
Origin
China
HS Code
850440999
Production Capacity
20000PCS Per Month

Product Description

                     S2800 380V Drive Inverter AC-DC-AC Motor Speed Controller
Product description
controlling Characteristics Control mode V/F control Vector control without PG
Output range of frequency 0.01~600.0Hz
Frequency setting analyzing degree 0.01Hz
Output frequency analyzing degree 0.01Hz
PWM load wave frequency Available to modulate from 0.5 to 15 kHz
Torque increase Vector control without PG:0.5Hz/150%(SVC)
Jog frequency 3 points can be set from 0.01 to 600.0Hz
Acceleration/deceleration time 0.01 to 3600.0 seconds. (Acceleration /deceleration time in 2 phases can be set separately)
Stall Prevention Level According to the load characteristics of motor, it' s available to be set as 100% to 200% of the rated current of the drive
DC braking braking 0 to 150% of the rated current. Starting time 0.0 to-50.0 sec, Stopping time 0.0-50.0 sec
Braking torque 20% (125% shall be available if connected with purchase braking resistor externally)          (1-25HP braking resistor is installed inside;30HP can connect externally with brake unit module)
speed regulation ratio Vector control without PG:1:100
Operation characteristics Frequency setting signal Digital Operator Set by UP and DOWN
External terminals 0-10VDC, 4-20mADC, Series Communication Board (RS-485)
Operation Signal Digital Operator Available to be operated by RUN, STOP and JOG keys.
External terminals 2 wire styles (Fwd/Stop, Rev/Stop, Run/Stop and Fed/Rev) /3 wire operation, JOG running, Serial Communication Board(RS-485)
Intelligent Input Terminal Speed shift can be preset in 8th phase ;the first/second acceleration and deceleration time shift: prohibition of acceleration and deceleration ;external interrupt ;inching operation ;increasing/decreasing frequency setting terminal
Intelligent Output Terminal During running, frequency arrival and output , , non-zero count agreement output, over torque output, external interrupt reference. Low voltage detection, operation mode reference, fault output and external fault interruption.
Analog signal output Correspond to actual output frequency or output current.
Fault signal contact For ac drive failure ,the contact is "on"(a relay with "c" contactor a open-collector output
Built-in Function Upper and lower limits setting of output frequency, instantaneous restart for abnormal malfunction, automatic voltage output regulation ,anomaly records ,parameter hold ,parameters reset to the factory defaults ,prohibition of reversion ,over-current stall prevention ,over-voltage stall prevention ,electronic  thermal relay
Protection Function Protection of inverter unit  phase ,accelerated over-current, decelerated over-current, constant-speed over-voltage, bus under-voltage failure, motor overload ,inverter overload ,open -phase at output side (75KW+models ),rectification modules overheating, overheating fault of inverter module ,external fault ,communication fault ,current detection fault ,motor self-learning fault ,EEPROM operational fault ,PID feedback disconnection fault, braking unit fault
Digital operator Consisting of 8 functional keys, 7 step LED in 5 digits; 5 status LED indicators. Available to set frequency, display actual output frequency, output current, self-determined unit parameter overview of users, modify settings and for parameter locking, fault displaying. Available to perform running, stop, reset, fwd/rev run and jog run.
Environment Operational Environment temperature -10° C to +50° C (+40° C ~ +50° C available when the dust cover is removed)
Storing temperature -20° C to + 60° C
Installation height Lower than 1000m, without corrosive gas, fluid and dust.
Vibration Below 20Hz 9.80665m/s² (1g), 20~50 Hz 5.88m/s² (0.6g)
Protection degrees IP20 (Determined by the installation environment of the end-users.)
S2800 380V Drive Inverter AC-DC-AC Motor Speed Controller

S2800 380V Drive Inverter AC-DC-AC Motor Speed Controller
S2800 380V Drive Inverter AC-DC-AC Motor Speed Controller S2800 380V Drive Inverter AC-DC-AC Motor Speed Controller

S2800 380V Drive Inverter AC-DC-AC Motor Speed Controller


Contact me
Contact person:Maggie Huang
Moblie:86-18650771915


 

Send your message to this supplier

*From:
*To:
avatar Ms. Ivy Shao
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now