Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items | S900E | ||
Power Supply | Rated voltage, Frequency | Single phase/Three phase 220V 50/60Hz | |
Voltage Range | 220V: 170V~240V | ||
Output | Voltage Range | 220V: 0~220V | |
Frequency Range | 0.10`400.00Hz | ||
Control method | V/F control, Space vector control. | ||
Indication | Operating status/Alarm definition/interactive guidance: eg, frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. | ||
Control Specifications | Output Frequency Range | 0.10Hz~400.00Hz | |
Frequency Setting Resolution | Digital input: 0.01Hz, analog input: 0.1% of maximum output frequency | ||
Output Frequency Accuracy | 0.01Hz | ||
V/F Control | Setting V/F curve to satisfy various load requirements | ||
Torque Control | Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque | ||
Multifunctional lnput Terminal | Six multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions | ||
Multifunctional Output Terminal | 2 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings | ||
Acceleration/deceleration Time Setting | 0~-999.9s acceleration/deceleration time can be set individually | ||
Other Functions | PID Control | Built-in PID control | |
RS485 | Standard RS485 communication function(MODBUS) | ||
Frequency Setting | Analog input: 0 to 10V, , 0 to 20mA can be selected; Dig ital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN | ||
Multi-speed | Six multifunction input terminals, 15section speed can be set | ||
Automatic voltage regulation | Automatic voltage regulation function can be selected | ||
Counter | Built – in 2group of counters | ||
Protection/ Warning Function | Overload | 150%, 60 second(Constant torque) | |
Over Voltage | Over voltage protection can be set | ||
Under Voltage | Under voltage protection can be set | ||
Other Protections | Overheat, short circuit, over current, and parameter lock and so on | ||
Environment | Ambient Temperature | -10° C to 40° C(non-freezing) | |
Ambient Humidity | Max. 95%(non-condensing) | ||
Altitude | Lower than 1000m | ||
Vibration | Max. 0.5G | ||
Structure | Cooling Mode | Forced air cooling | |
Protective Structure | IP20 | ||
Installation | Mode | Wall Mounted |
Model | Input | Rate output Power(kw) | Capacity (KVA) | Output Current (A) | Overload capacity (60s)(A) | Applicable motor(KW) |
S900-2S0.4GE | Single phase AC 220V. 50/60Hz | 0.4 | 1 | 2.2 | 3.75 | 0.4 |
S900-2S0.75GE | Single phase AC 220V. 50/60Hz | 0.75 | 2 | 5 | 7.5 | 0.75 |
S900-2S1.5GE | Single phase AC 220V. 50/60Hz | 1.5 | 2.8 | 7 | 10.5 | 1.5 |
S900-2S2.2GE | Single phase AC 220V. 50/60Hz | 2.2 | 4.5 | 11 | 16.5 | 2.2 |
S900-4T0.75GE | Three phase AC 380V. 50/60Hz | 0.75 | 2.2 | 2.7 | 4.05 | 0.75 |
S900-4T1.5GE | Three phase AC 380V. 50/60Hz | 1.5 | 3.2 | 4 | 6 | 1.5 |
S900-4T2.2GE | Three phase AC 380V. 50/60Hz | 2.2 | 4 | 5 | 7.5 | 2.2 |
Model | A | B | C | Φ D | E | F |
S900-2S0.4GE | 141.5 | 85.0 | 130.5 | 5.0 | 113 | 74 |
S900-2S0.75GE | 141.5 | 85.0 | 130.5 | 5.0 | 113 | 74 |
S900-2S1.5GE | 141.5 | 85.0 | 130.5 | 5.0 | 113 | 74 |
S900-2S2.2GE | 151 | 100 | 139.6 | 5.2 | 111.7 | 88.6 |
S900-4T0.75GE | 151 | 100 | 139.6 | 5.2 | 111.7 | 88.6 |
S900-4T1.5GE | 151 | 100 | 139.6 | 5.2 | 111.7 | 88.6 |
S900-4T2.2GE | 151 | 100 | 139.6 | 5.2 | 111.7 | 88.6 |