Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | MSI solar inverter | |
Main control method | control method | V/F control, Space vector control. |
Output Frequency Range | 0~400.0Hz | |
Carrier frequency Setting | 0~15kHz | |
Frequency Setting Resolution | Digital input: 0.1Hz | |
Analog input: 0.1% of max. frequency | ||
Accuracy of output frequency | 0.1Hz | |
Overload | Type G: 150% rated current in 60s; 180% rated current in 3s. | |
Type P: 120% rated current in 60s; 150% rated current in 3s. | ||
Torque control accuracy | Auto boost; customized boot 0.0~20.0% | |
V/F control | Can be arbitrarily set line V/F | |
PLC, Multi-speed operation | Internal PLC or input terminals able can be set 16 section | |
Internal PID | it realizes process-controlled closed loop control system easily. | |
Voltage | 0~220VAC; 0~380VAC | |
Acceleration and deceleration time settings | 0~999.9s Respectively provided acceleration and deceleration time | |
Communication methods | RS -485 | |
Operation | Running command channel | Operation panel, control terminal, Seriel communication port |
Frequency source | Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. | |
Input terminal | six digital input terminal; two analog input terminal: one just support input voltage 0~10V (FIV), other support input current 4~20mA (FIC) | |
Output terminal | one digital output terminal ( M01); one relay output terminal ( RA, RB, RC) | |
one analog output terminal, support output voltage 0~10V (FOV) | ||
Control panel | LED screen | display parameters |
Protection function | Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, under voltage protection, overheat protection and overload protection | |
Environment | Installation location | Indoor, free from direct sunlight, dust, corrosive gas,combustible gas, oil smoke, vapour, drip or salt. |
Altitude | Lower than 1000 m | |
Ambient temperature | -10°C ~40°C (de-rated if the ambient temperature is between 40°C and 50°C) | |
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9 m/s2 (0.6 g) | |
Storage temperature | -20°C~60°C | |
Class protection | IP20 |