Input voltage grade | 220V | 440V | ||||||||||
Type S900-2S/4TXXXG | 0.2 | 0.4 | 0.75 | 1.5 | 2.2 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | ||
Output | Max suitable motor output power(KW) | 0.2 | 0.4 | 0.75 | 1.5 | 2.2 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | |
Max suitable motor output power(HP) | 0.25 | 0.5 | 1 | 2 | 3 | 0.5 | 1 | 2 | 3 | 5 | ||
Output rated capacity(KVA) | 0.6 | 1 | 1.9 | 2.5 | 4.2 | 1.2 | 2.3 | 3.2 | 4.2 | 6.3 | ||
Output rated current(A) | 1.6 | 2.5 | 4.2 | 7.5 | 11 | 1.5 | 2.5 | 4.2 | 5.5 | 8.2 | ||
Output frequency range | 0.1-400Hz | |||||||||||
Overload capacity | 150% of rated output current and run for 60sec. | |||||||||||
Input | Number of phase, voltage, frequency | Single phase 200-240.50/60Hz |
Three phase 380-460V, 50/60Hz |
|||||||||
Allowable variation range for V & Hz | Voltage±10%, Frequency±5% | |||||||||||
Input current(A) | 4.9 | 6.5 | 10 | 17.5 | 27 | 1.9 | 3.5 | 6 | 7.2 | 9 | ||
Cooling system | Natural cooling | Forced cooling | Natural cooling air | Forced cooling | ||||||||
Control features | Control mode | Adopt SVPWM or quasi SPWM modulation techniques | ||||||||||
Output frquency range | 0.1-400Hz | |||||||||||
Frequency setting resolution | 0.1Hz | |||||||||||
Output frequency resolution | 0.1Hz | |||||||||||
PWM carrier frequency | Can regulate between 2-12KHz | |||||||||||
Torque ascending | Automatic torque ascending and automatic slip compensation Start torque to achieve 150% rated torque for 5Hz hours | |||||||||||
Hopping frequency | Can set 3points from 0.1 to 400Hz | |||||||||||
Acceleration/ Deceleration time | 0.1-600 seconds(2 section acceleration/deceleration can be set separately) | |||||||||||
Stall prevention level | Can be set according to 50-200% of rated current formotor overload features | |||||||||||
DC brake | Stop automatic 0.1-60.0Hz operation,brake current 0-100% rated current,starting time is 0-60.0sec,stopping time 0-60.0sec | |||||||||||
V/F curve | Settable V/F curve | |||||||||||
Operation features | Frequency setting signal | Digital operator | Can be set by keys | |||||||||
External signals | Potentionmeters 5KΩ.0-10VDC,4-20mADC,multifunction input option 3-5(7 section speed;inch dynamitic,up/down instruction),serial Communication port(RS485) | |||||||||||
Running operation signals | Digital operator | Can be operated with RUNandSTOPkeys | ||||||||||
External terminal | 2 line type(Fwd/Stop Rev/Stop Run/Stop Fwd/Rev)/3 line type operation,inch dynamic operation,serial communication port(RS485) | |||||||||||
Intelligent input terminal | 7 section preset speed switch,the first,second acceleration time switch,acceleration and deceleration is forbidden,external disconnection input,Inch dynamicoperation,increasing/decreasing frequency terminal set,counter terminal | |||||||||||
Intelligent output terminal | While operating,frequency reaches output and non zerospeed,counter reaches output,over torque output,external disconnection indicator | |||||||||||
Analog signal output | Corresponding to output current,output frequency1(before slip compensation),output frequency2(after slipcompensation),output voltage,power consumption,directcurrent bus voltage | |||||||||||
Built in function | Upper limit and lower limit of output frequency shall beset,momentary interruption restart,abnormal malfunction restart, automatic constant output regulation,abnormal records,parameter shutting,factory parameter reset,reversal is forbidden,over current stall prevention,over-voltage stall prevention,electronic thermal relay | |||||||||||
Protection function | Overvoltage,over current,external abnormality disconnection input,motor overload,driver overload anddriver overheat | |||||||||||
Digital operator | Includes 6 function keys,4digital 7section LED displayer,4 status indicator LED lights,frequency can be set,actual output frequency and output current can be shown,the user shall self-define unit parameter scanning and modify set and parameter shutting,abnormal malfunction display can be operated,stopped,reset,forwarded and reversed. | |||||||||||
Environment | Operation environment temperature | -10ºC to +50ºC(parallel installation shall be carried out +40ºC without dew formation or ice formation) | ||||||||||
Storage temperature | -20ºC to +60ºC | |||||||||||
Operation environment humidity | There is no dew formation below 90%RH | |||||||||||
Installation height | The height is below 1000 meters(there is no corrosivegas,liquid or dust) |