Model |
S2100S |
Input |
Rated voltage,Frequency |
3 AC 380V / 220V; 50-60 Hz |
Voltage Range |
380V: 330V~440V;220V: 170-240V |
Output |
Voltage Range |
380 V: 0~380 V; 220V: 0-220V |
Frequency Range |
0.10~400.0 Hz |
Control method |
V/F control,Space verctor control |
Indication |
Operating status/Alarm definiton/interactive guidance;eg,frequency setting,the output frequecy/current,DC bus voltage,the temperature and so on. |
Control Specification |
Output Frequency Range |
0.10~400.00 Hz. |
Frequency Setting Resolution |
Digital input: 0.01 Hz.
Analog input:0,1% of maximum output frequency |
Output Frequency Accuracy |
0.01 Hz. |
V/F Control |
Setting V/F curve to satisfy various load requirements |
Torque Control |
Auto increase:auto riase torque by loading condition;Manual increase:enable to set 0.0~20% of raising torque |
Multifuncional Input Terminal |
8 multi-function input terminals,realizing fuctions including fifteen section speed control,program running, four-section acceleration/deceleration speed switch,UP/DOWN function and emergency stop and other functions |
Multifuntional Output Terminal |
3 multi-function output terminals for displaying of running,zerospeed,counter,external abnormity,program operation and other infornation and warnings |
8 multifunitinal output terminals, 1 inverter can control 4 ciircular variable frequency pumps |
Acceleration/deceleration Time Setting |
0~6000 s acceleration/deceleration time can be set individually |
Other functions |
PID Control |
Built-in PID control |
RS485 |
Standard RS485 communication function (MODBUS) |
Frequency Setting |
Analog input 0~10V, 0~20, can be selected; Digital input: input using the setting dial of the operation panel or RS 485 or UP/DOWN |
Multi-speed |
Eight multifunction input terminals,15 section speed can be set |
Automatic voltage regulation |
Automatic voltage regulation function can be selected |
Counter |
Built-in 2 group of counters |
Overload |
120%,60second (variable torque) |
Over Voltage |
Over voltage protection can be set |
Under Voltage |
Under voltage protection can be set |
Other Protections |
Overheat,output shortcircuit,over current,and parameter lock and so on. |
Environment |
Ambient Temperature |
-10ºC~40ºC(non-freezing) |
Ambient Humidity |
Max. 95% (non-condensing) |
Altitude |
Lower than 1000. |
Vibration |
Max. 0.5 g |
Structure |
Cooling Mode |
Below 3.7 kW no have fan; Above 5.5 kW Forced air cooling |
Protective Structure |
IP 65 |
Model |
Suitable Motor |
Output Current |
Assembly Dimension(mm) |
W |
H |
D |
A |
B |
b |
S2100-2S0.75GS |
0.75KW |
5 |
188 |
122 |
134 |
105 |
178 |
M4 |
S2100-2S1.5GS |
1.5KW |
7 |
S2100-2S2.2GS |
2.2KW |
11 |
S2100-4T0.75GS |
0.75KW |
2.7 |
188 |
122 |
134 |
105 |
178 |
M4 |
S2100-4T1.5GS |
1.5KW |
4 |
S2100-4T2.2GS |
2.2KW |
5 |
S2100-4T3.7GS |
3.7KW |
8.6 |
235 |
154 |
179 |
125 |
221 |
M4 |
S2100-4T5.5GS |
5.5KW |
12.5 |
S2100-4T7.5GS |
7.5KW |
17.5 |
S2100-4T11GS |
11KW |
24 |
Function:
· To achieve the water supply control system with more than 6 sets of Pumps, one set is the Main Engine, others 5 sets are machine as attached engine
· The function for the main engine: Any set can be the main engine. Once the current main engine occur the breakdown ,can exchange another set to be the main engine. But the signal line of the Pressure Sensor must be moved to the new main engine accordingly .· The function of Adding Pump and reducing Pump: Finish the several Pump according to the Adding and Reducing.
· With the resting state and Awaken Function
· With the function of exchange Pump on timely
· With the function of Antifreeze and waterproof.
· With the function for exchanging the Pump automatically when occur the breakdown. Once any set of the machine appears the mistake, the system will overleap this part automatically .To be ensure the stability of the system .
· Alarm for watering :With the alarming function for HO,LO ,LP
" Machtric"
Focused on Customer Automation Soultion & Represents
Machtric --------------------"We care for your business
If you have any questions, pls don`t hesitate contace with Alice .