380V 4kw New AC Motor Drive/Varibale Speed Drives/Frequency Inverter/VFD

Application: High-performance Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Samples:
US$ 59/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
S800E inverter
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type
Brand
Machtric AC Drive
Speed Range
1:100(SVC)
Power Range
0.75~5.5kw
Voltage Range
110V/220V & 380 V
Frequency Range
1:100(SVC)
VFD
Variable Frequency Drive
Transport Package
Carton
Specification
CE
Origin
China
HS Code
8504409999
Production Capacity
50000

Product Description

Items S800E
Power
Supply
Rated voltage, Frequency  
One-phase/Three-phase AC 220V 50/60Hz
Voltage Range  
220V: 170~240V
Output Voltage Range 220V: 0~220V
Frequency Range 0.10~400.00Hz
Control method V/F control, Space vector control.
Indication Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/ current, DC bus voltage, the temperature and so on.
            Control   SpeciAlations Output Frequency
Range
0.10Hz~400.00Hz
Frequency Setting
Resolution
Digital input: 0.01Hz, analog input: 0.1% of
maximum output frequency
Output Frequency
Accuracy
0.01Hz
V/F Control Setting V/F curve to satisfy various load
Requirements.
Torque
Control
Auto increase: auto raise torque by loading
Condition; Manual increase: enable to set
0.0~20.0% of raising torque.
Multifunctional
Input Terminal
Four multi-function input terminals, realizing
functions including fifteen section speed control, Program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions
Multifunctional
Output Terminal
1 multi-function output terminals for displaying
of running, zero speed, counter, external
abnormity, program operation and other
Information and warnings.
Acceleration/ deceleration Time Setting 0~999.9s acceleration/deceleration time can be set individually.
                 Other      functions
 
PID Control Built-in PID control
RS485 Standard RS485 communication function(MODBUS)
Frequency Setting Analog input: 0 to 10 V, 0 to 20mA can be
selected;
Digital input:Input using the setting dial of the
operation panel or RS485 or UP/DOWN.
Note:AVI terminals can be used to select an
analog voltage input(AV) and analog current
input(AI) through the switch J2.
Note: AVI terminals can be used to select an
Analog voltage input (AV) and analog current
Input(AI) through the switch J2.
Multi-speed Four multifunction input terminals, 15 section
speed can be set
 
   Protection/Warning
       Function             
Overload 150%, 60 second(Constant torque)
Over Voltage Over voltage protection can be set.
Under Voltage Under voltage protection can be set
Other Protections Overheat,output short circuit,over current, and
Parameter lock and so on.
   Environment Ambient Temperature -10ºC to 40ºC(non-freezing)
Ambient Humidity Max. 95% (non-condensing)
Altitude Lower than 1000m
Vibration Max.0.5G
Structure Cooling Mode Forced air cooling
Protective
Structure
IP 20
Installation Mode Wall-mounted or standard 35MM rail mounting
Product series models
Model Input Power
Output
(KW)
Capacity
(KVA)
Current
Output
(A)
Load
Capacity
(60s)(A)
Motor
Equipped
(KW)
S800-2T0.4GE 1PH/3PH
220V-
50/60HZ
0.4 1.0 2.5 3.75 0.4
S800-2T0.75GE 0.75 2.0 5.0 7.50 0.75
S800-2T1.5GE 1.5 2.8 7.0 10.50 1.5
Main Circuit Wiring NoticeThe S800E series is a highly reliable product, but incorrect peripheral circuit making or operation/handing method may shorten the product life or damage the product.
Before starting operation, always recheck the following items.
 
Use crimping terminals with insulation sleeve to wire the power supply and motor.
 
Application of supply power to the output terminals( U,V,W) of the inverter will damage the inverter. Never perform such wiring.
 
 
After wiring, wire offcuts must not be left in the inverter. Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean. When drilling mounting holes in an enclosure etc., take are not to allow chips and other foreign matter to enter the Inverter.
 
This inverter must be earthed. Earthing must conform to the requirements of national and local safety regulations and electrical codes.
 
Use the thickest possible earth cable.
 
 
Then grounding point should be as near as possible to the inverter, and the ground wire length should be as short as possible.
 
Where possible, use independent earthing for the inverter. If Independent earthing is impossible, use joint earthing(,) where the inverter is connected with the other equipment at an earthing point.Joint earthing as in ()must be avoided as inverter is
connected with the other equipment by a common earth cable



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
Registered Capital
73901.09 USD
Management System Certification
ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001