• S3100A General Application Heavy Torque 380V AC Drive 0.75kw 1.5kw Savch VFD
  • S3100A General Application Heavy Torque 380V AC Drive 0.75kw 1.5kw Savch VFD
  • S3100A General Application Heavy Torque 380V AC Drive 0.75kw 1.5kw Savch VFD
  • S3100A General Application Heavy Torque 380V AC Drive 0.75kw 1.5kw Savch VFD
  • S3100A General Application Heavy Torque 380V AC Drive 0.75kw 1.5kw Savch VFD
  • S3100A General Application Heavy Torque 380V AC Drive 0.75kw 1.5kw Savch VFD

S3100A General Application Heavy Torque 380V AC Drive 0.75kw 1.5kw Savch VFD

Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: High Voltage Variable-Frequency Drive
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
S3100A
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Textile Special, Heavy Loading Machines
Brand
Machtric
Item Name
Savch VFD
Carrier Frequency
1-15kHz
Control Mode
V/F Control/ Vector Flux Control
Output Power
220V(0.4-2.2kw);380V(0.75-400kw)
Multi Speed
16 Segments Speed
Jog Frequency Range
0.00-50.00Hz
Pid Control
Built-in
with C3 Filter
Yes
Maximum Frequency
600.00Hz
Interface RS-485
Standard RS485 Communication Function
Transport Package
Standard Export Packing
Specification
Depends on different voltage/frequency range
Trademark
Machtric
Origin
China
HS Code
850440999
Production Capacity
5000 Pieces Per Month

Product Description

S3100A General Application Heavy Torque 380V AC Drive 0.75kw 1.5kw SAVCH VFD
 

Product Specification:
  Item Detailed information 
control characteristic control mode V/F  control , open loop vector control , torque control 
range of output frequency  0-500.00Hz(v/f highest 3200.0Hz)
frequency setting resolution 0.01Hz
ouput frequency setting resolution  0.01Hz
PWM carrier frequency  adjust from 0.5Khz to 12khz
torque boost open loop vector control(SVC):G type:0.5Hz/150%,P type 0.5Hz/120%
V/F curve three types :line, multi-point. Nth power v/f curve
(1.2th power ,1.4th power ,1.6th power ,  1.8th power ,2th power
v/f separation  twp types : full separation , semi-separation
Jump frequency  adjust from 0.1hz to 500.00hz
acceleration/deceleration time  0.00 to 65000 seconds(4-stage acceleration/deceleration time is set independetly)linear or S-curve acceleration/deceleration mode
over current stall prevention level can be set according to the motor load charactreristics with 100-200% of the rated current of the driver
DC brake  when stopping , it can be operated from 0.00 to the maximum operating frequency , and the braking current is 0 to 100% of the rated current;Start time 0-100.0 seconds, stop time 0-100.0 seconds
Brake torque 20%(external optional brake resistor can reach 125%)
(1-30HP brake transistor built-in,40HP and above can be connected to the external brake unit module
operation charactreistic Speed ratio open loop vector control :1:100
Frequency  setting signal bit operation board :set by 
external terminal :0-10VDC,4-20mADC, Serial communication(RS485)
Operation signal bit operation board :Available to be oerated by RUN, STOP, JOG keys
external terminal :2-wire/ 3-wire operation ,jog operation , serial communication(RS485)
Input terminal of multi-function Forward and reverse running, three-wire operaton control, Forward and reverse jog running,free stop, reset fault, running pause, external fault input, increment /decrement frequency terminal setting,16-segment prese speed switching,acceleration/deceleration time switching ,frequency
source switching, running command switching,PID control, PLC status
 reset, pause swing frequency, reset swing frequency, prohibit acceleration and deceleration, disable torque control, calculator function, length count frequency increase and decrease setting clear, high speed pulse
 frequency , stop DC braking, frequency modification enable, speed control and torque control switching, clear running time of this time.
 
output terminal of multi-function Inverter operation, fault output, frequency level detection FDT output
 frequency arrival, zero speed operation,overload pre-alarm count value arrival length arrival, PLC cycle completion, cumulative running time
Item Detailed  information
  arrival ,frequency limitation , torque limit ready to run , ACI1>AVI2, upper limit frequency  arrival ,lower limit frequency arrival(operation related). undervoltage status output, communication setting , cumulative power-on time arrival , frequency arrival output , timing arrival output, offload , recerse
In operation , the zero current state, the module temperature reaches , the output current exceeds the limt, the lower limit frequency  arrives(the stop is also output ) the alarm output (contrinues to run ) and the running time arrives
analog signal output corresponding to the actual output frequency , output current , output voltage,etc.
fault signal contact  contact"ON"(one "C" contract relay or two open collector outputs when the AC drive fails
inner function
 
 Output frequency upper and lower limit seing, instantaneous power failure restart abnormal fault restart speed tracking
 Simple PLC.multi-speed operation,PID control, timing control Automatic regulated output regulation
 Abnormal record. parameter lock, parameter factory reset
 Reverse rotation prohibited,overcurent stall prevention, overvoltage stall prevention, electronic thermal relay
 
protection function  Short circuit protection, acceleration over current, deceleration over current, constant speed over current, acceleration over voltage.
 deceleration over voltage, constant speed over voltage, bus undervoltage fault. motor overload. inverter overload. over torque protection, loss phase protection function  on the input (7.5G/11P and above),loss phase on the output , module
 overheating. external fault, communication fault, current detection fault. motor self-leaming faut, parameter read and write abnormality, inverter hardware abnormality, motor short circuit to ground., running time arrival. the power-on time arrives, the load dropped. the PID feedback disconnected. and the fast current limit timeout
   number of part on keypad Contains 8 function keys,5-digit8-segment LED display,7 status indicato LED lightsCan set the frequency,display the actual output frequency.
output current, user-defined unit Parameter browsing and modification settings and parameter locking,abnormal fault display
Executable operation, stop,reset, forward/reverse, jogging
environment operation  temperature  _10ºC to + 50ºC( + 40ºC~ + 50ºC below 90% RH, No condensation)
temperature of stock .-20ºC to .+60ºC
humidity of opeation environment belowe 90%RH,NO  condenstaion 
height  of installtion  no more than 1000m in height, no corrorsive gas, liquid , dust
vibation  Below 20Hz 9.80665m/s²(1g), 20-50Hz 5.88m/s²(0.6g)
enclosure IP20(Depending on the end customers`s installation environment)
Note: the instantaneous power failure compensation time varies due to the inverter capacity.If a long instataneouspower failure time is required, the external"instantaneous power failure compensation device can be added

2.Detail Picture:
S3100A General Application Heavy Torque 380V AC Drive 0.75kw 1.5kw Savch VFD
S3100A General Application Heavy Torque 380V AC Drive 0.75kw 1.5kw Savch VFD




 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
Registered Capital
73901.09 USD
Management System Certification
ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001