Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | 1/3 Phase |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
0.75kw frequency drive inverter with V/F control, 120v single phase input to 1ph/3ph 220v output. With an IP20 enclosure rating and air cooling, the frequency inverter runs single-phase and three-phase motors and works at (-10ºC, 40ºC). Offer RS485 communication interface. Easy to install and operate.
Basics | Model | Z900-2S0.75GE |
Capacity | 0.75 kW (1 hp) | |
Shipping weight | 3 kg | |
Dimension (W x H x D) | 120*205*166 mm | |
I/O Feature | Rated current | 4 A |
Input voltage | 1 phase 120V AC ±15% | |
Input frequency | 50Hz/60Hz | |
Output voltage | 1 phase or 3 phase 220V AC ±15% | |
Output frequency |
0~320Hz (SFC) |
|
Control Feature | Control mode | V/F control; vector control |
Communication | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |
Speed regulation | 1:100 | |
Start torque | 150% of rating torque at 1 Hz | |
Speed control accuracy | ≤±0.5% of rating synchronous speed | |
Frequency precision | Digital setting: max frequency x± 0.01%; | |
Analog setting: max frequency x± 0.2% | ||
Frequency resolution | Analog setting: 0.1% of max frequency; | |
Digital setting: 0.01Hz | ||
Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
Interior PID controller | Be convenient to make closed-loop system | |
Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
Environment | Enclosure rating | IP 20 |
Temperature | -10ºC~ +40ºC; VFD will be derated if ambient temperature exceed 40ºC; each rise 1ºC, the derate will be 5% | |
Humidity | smaller than 95%RH, non-condensation | |
Altitude | ≤1000m; VFD will be derated if above 1000m | |
Vibration | Less than 5.9 m/s2 (0.6 g) | |
Cooling | forced air cooling | |
Store environment | -20ºC~ +60ºC; no dust, no corrosive gas, no direct sunlight |
Model | Input | Rate output Power (kw) |
Capacity (KVA) |
Output Current (A) |
Overload capacity (60s)(A) |
Applicable motor (KW) |
Z900-2S0.4GE | Single phase AC 220V.50/60Hz | 0.4 | 1 | 2.2 | 3.75 | 0.4 |
Z900-2S0.75GE | Single phase AC 220V.50/60Hz | 0.75 | 2 | 5 | 7.5 | 0.75 |
Z900-2S1.5GE | Single phase AC 220V.50/60Hz | 1.5 | 2.8 | 7 | 10.5 | 1.5 |
Z900-2S3.7GE | Single phase AC 220V.50/60Hz | 3.7 | 6.8 | 8.6 | 12.9 | 3.7 |
Z900-4T0.75GE | Three phase AC 380V.50/60Hz | 0.75 | 2.2 | 2.7 | 4.05 | 0.75 |
Z900-4T1.5GE | Three phase AC 380V.50/60Hz | 1.5 | 3.2 | 4 | 6 | 1.5 |
Z900-4T2.2GE | Three phase AC 380V.50/60Hz | 2.2 | 4 | 5 | 7.5 | 2.2 |
Z900-4T3.7GE | Three phase AC 380V.50/60Hz | 3.7 | 6.8 | 8.6 | 12.9 | 3.7 |
Z900-4T5.5GE | Three phase AC 380V.50/60Hz | 5.5 | 10 | 12.5 | 18.75 | 5.5 |
Z900-4T7.5GE | Three phase AC 380V.50/60Hz | 7.5 | 14 | 17.5 | 21 | 7.5 |
Z900-4T11GE | Three phase AC 380V.50/60Hz | 11 | 19 | 24 | 36 | 11 |
Z900-4T15GE | Three phase AC 380V.50/60Hz | 15 | 26 | 33 | 45 | 15 |
Z900-4T18.5GE | Three phase AC 380V.50/60Hz | 18.5 | 32 | 40 | 60 | 18.5 |
Z900-4T22GE | Three phase AC 380V.50/60Hz | 22 | 37 | 47 | 70.5 | 22 |