Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Msi solar inverter | |
Main control method | Control method | V/f control, space vector control. |
Output frequency range | 0~400.0hz | |
Carrier frequency setting | 0~15khz | |
Frequency setting resolution | Digital input:0.1hz | |
Analog input:0.1% of max.Frequency | ||
Accuracy of output frequency | 0.1hz | |
Overload | Type g:150% rated current in 60s;180% rated current in 3s. | |
Type p:120% rated current in 60s;150% rated current in 3s. | ||
Torque control accuracy | Auto boost;Customized boot 0.0~20.0% | |
V/f control | Can be arbitrarily set line v/f | |
Plc, multi-speed operation | Internal plc or input terminals able can be set 16 section | |
Internal pid | It realizes process-controlled closed loop control system easily. | |
Voltage | 0~220vac;0~380vac | |
Acceleration and deceleration time settings | 0~999.9s respectively provided acceleration and deceleration time | |
Communication methods | Rs -485 | |
Operation | Running command channel | Operation panel, control terminal, seriel communication port |
Frequency source | Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. | |
Input terminal | Six digital input terminal;Two analog input terminal:One just support input voltage 0~10v (fiv), other support input current 4~20ma (fic) | |
Output terminal | One digital output terminal ( m01);One relay output terminal ( ra, rb, rc) | |
One analog output terminal, support output voltage 0~10v (fov) | ||
Control panel | Led screen | Display parameters |
Protection function | Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, overvoltage protection, under voltage protection, overheat protection and overload protection | |
Environment | Installation location | Indoor, free from direct sunlight, dust, corrosive gas,combustible gas, oil smoke, vapour, drip or salt. |
Altitude | Lower than 1000 m | |
Ambient temperature | -10°c ~40°c (de-rated if the ambient temperature is between 40°c and 50°c) | |
Humidity | Less than 95%rh, without condensing | |
Vibration | Less than 5.9 m/s2 (0.6 g) | |
Storage temperature | -20°c~60°c | |
Class protection | Ip20 |