Input Voltage |
220V |
440V |
Model number: S1100-2T/4T***G |
0.75 |
1.5 |
2.2 |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
Output |
Applicable motor power (KW) |
0.75 |
1.5 |
2.2 |
0.75 |
1.5 |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
Output rated current (A) |
5 |
6.5 |
11 |
3.0 |
4.2 |
5.5 |
8.2 |
13 |
18 |
24 |
32 |
38 |
45 |
Max output voltage (A) |
Input power |
Over load capacity |
150% of rated output current and run for 65 seconds |
Power |
Phase. Voltage. Frequency |
1-phase/3-phase 200-240V 50/60HZ |
3-phase 380-460V 50/60HZ |
Allowable variation range of Voltage Frequency |
Voltage: ± 15% Frequency: ± 5% |
Input current (A) |
11/7.4 |
15/10 |
27/15 |
4.2 |
6.0 |
7.2 |
8.5 |
14 |
20.6 |
28 |
30 |
39 |
49 |
Controlling Characteristics |
Control mode |
Adopting SVPWM modulating techniques (V/F control and Speed Sensor-less Vector) |
Output range of frequency |
0.01~400.0Hz |
Frequency setting analyzing degree |
0.01Hz |
Output frequency analyzing degree |
0.01Hz |
PWM load wave frequency |
Available to modulate from 2 to 10kHz |
Torque increase |
Auto torque-increase and auto slip compensation at 2 Hz the starting torque can reach 150% of rated torque. |
Jog frequency |
3 points can be set from 0.01 to 400.0Hz |
Acceleration/deceleration time |
0.01 to 600.0 seconds. (2 steps of accel/decel time can be set separately. ) |
Stall Prevention Level |
According to the load characteristics of motor, it' s available to be set as 50 to 200% of the rated current of the drive |
DC braking |
Available to be operated from 0.01 to 400.0 Hz from STOP, braking 0 to 100% of the rated current. Starting time 0.0 to-60.0 sec, Stopping time 0.0-60.0 sec |
Braking torque |
20% (125% shall be available if connected with purchase braking resistor externally) (or 1 to 25HP, equipped within the electric crystals, for 30 HP, braking unit module shall be connected externally. ) |
V/F curve |
V/F curve available to be set |
Operation characteristics |
Frequency setting signal |
Digital Operator |
Set by UP and DOWN |
External terminals |
0-10VDC, 4-20mADC, Series Communication Board (RS-485) |
Running operatisignal |
Digital Operator |
Available to be operated by RUN, STOP and JOG keys. |
External terminals |
2 wire styles (Fwd/Stop, Rev/Stop, Run/Stop and Fed/Rev) /3 wire operation, JOG running, Serial Communication Board(RS-485) |
Intelligent Input Terminal |
Switching of 16 step pre-set available speed; Switching of First/Second acceleration/deceleration time; prohibiting acceleration/deceleration and external interrupt input; Jog running UP/DOWN frequency terminal setting; Count terminals |
Intelligent Output Terminal |
During running, frequency agreement output, non-zero count agreement output, over torque output, external interrupt reference. Low voltage detection, operation mode reference, fault output and external fault interruption. |
Analog signal output |
Correspond to actual output frequency or output current. |
Fault signal contact |
Contact of ON at AC motor drive (Relay with one C contact or two open collector output. ) |
Built-in Function |
Setting max/min output frequency; momentary power off restarting; fault restaring; setting of S curve acceleration/deceleration time; auto-voltage stabilizing output modulation; digital frequency output signal; fault records; parameters locking; reset to factory setting; inhibiting reverse run; over current stalling prevention, over voltage stalling prevention, electrical thermal relay. |
Protection Function |
Over current; over voltage, low voltage; external fault interruption input; motor over load; GFF: grounding protection(For optional use); over load of the drive and drive overheating |
Digital operator |
Consisting of 8 functional keys, 7 step LED in 5 digits; 5 status LED indicators. Available to set frequency, display actual output frequency, output current, self-determined unit parameter overview of users, modify settings and for parameter locking, fault displaying. Available to perform running, stop, reset, fwd/rev run and jog run. |
Environment |
Operational Environment temperature |
-10° C to +50° C (+40° C ~ +50° C available when the dust cover is removed) |
Storing temperature |
-20° C to + 60° C |
Installation height |
Lower than 1000m, without corrosive gas, fluid and dust. |
Vibration |
Below 20Hz 9.80665m/s² (1g), 20~50 Hz 5.88m/s² (0.6g) |
Protection degrees |
Determined by the installation environment of the end-users. |