Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | 1/3 Phase |
Still deciding? Get samples of US$ 220/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items |
Z900E |
|
Power Supply |
Rated voltage, Frequency | Single phase/Three phase 220V 50/60Hz |
Voltage Range | 220V:170V~240V 380V:330~440V | |
Output | Voltage Range | 220V:0~220V,380V:0~380V |
Frequency Range | 0.10`400.00Hz | |
Control method | Sensor less flux vector control (SFVC) Voltage/Frequency (V/F) control |
|
Indication | Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. | |
Control Specifications | Output Frequency Range | 0.10Hz~400.00Hz |
Frequency Setting Resolution | Digital input:0.01Hz, analog input:0.1% of maximum output frequency | |
Output Frequency Accuracy | 0.01Hz | |
V/F Control | Setting V/F curve to satisfy various load requirements | |
Torque Control | Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque | |
Multifunctional input Terminal |
Six multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions | |
Multifunctional Output Terminal |
2 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings | |
Acceleration/deceleration Time Setting | 0~-999.9s acceleration/deceleration time can be set individually | |
Other Functions | PID Control | Built-in PID control |
RS485 | Standard RS485 communication function(MODBUS) | |
Frequency Setting | Analog input:0 to 10V,,0 to 20mA can be selected; Dig ital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN |
|
Multi-speed | Six multifunction input terminals, 15section speed can be set | |
Automatic voltage regulation | Automatic voltage regulation function can be selected | |
Counter | Built -in 2group of counters | |
Protection/ Warning Function |
Overload | 150%,60 second(Constant torque) |
Over Voltage | Over voltage protection can be set | |
Under Voltage | Under voltage protection can be set | |
Other Protections | Overheat, short circuit, over current, and parameter lock and so on | |
Environment | Ambient Temperature | -10ºC to 40ºC(non-freezing) |
Ambient Humidity | Max.95%(non-condensing) | |
Altitude | Lower than 1000m | |
Vibration | Max. 0.5G | |
Structure | Cooling Mode | Forced air cooling |
Protective Structure | IP20 | |
Installation | Mode | Wall Mounted |
Model | Input | Rate output Power (kw) |
Capacity (KVA) |
Output Current (A) |
Overload capacity (60s)(A) |
Applicable motor (KW) |
Z900-2S0.4GE | Single phase AC 220V.50/60Hz | 0.4 | 1 | 2.2 | 3.75 | 0.4 |
Z900-2S0.75GE | Single phase AC 220V.50/60Hz | 0.75 | 2 | 5 | 7.5 | 0.75 |
Z900-2S1.5GE | Single phase AC 220V.50/60Hz | 1.5 | 2.8 | 7 | 10.5 | 1.5 |
Z900-2S3.7GE | Single phase AC 220V.50/60Hz | 3.7 | 6.8 | 8.6 | 12.9 | 3.7 |
Z900-4T0.75GE | Three phase AC 380V.50/60Hz | 0.75 | 2.2 | 2.7 | 4.05 | 0.75 |
Z900-4T1.5GE | Three phase AC 380V.50/60Hz | 1.5 | 3.2 | 4 | 6 | 1.5 |
Z900-4T2.2GE | Three phase AC 380V.50/60Hz | 2.2 | 4 | 5 | 7.5 | 2.2 |
Z900-4T3.7GE | Three phase AC 380V.50/60Hz | 3.7 | 6.8 | 8.6 | 12.9 | 3.7 |
Z900-4T5.5GE | Three phase AC 380V.50/60Hz | 5.5 | 10 | 12.5 | 18.75 | 5.5 |
Z900-4T7.5GE | Three phase AC 380V.50/60Hz | 7.5 | 14 | 17.5 | 21 | 7.5 |
Z900-4T11GE | Three phase AC 380V.50/60Hz | 11 | 19 | 24 | 36 | 11 |
Z900-4T15GE | Three phase AC 380V.50/60Hz | 15 | 26 | 33 | 45 | 15 |
Z900-4T18.5GE | Three phase AC 380V.50/60Hz | 18.5 | 32 | 40 | 60 | 18.5 |
Z900-4T22GE | Three phase AC 380V.50/60Hz | 22 | 37 | 47 | 70.5 | 22 |