Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | 1/3 Phase |
Still deciding? Get samples of US$ 116/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items | S900GS |
||
Power Supply |
Rated voltage, Frequency | Single phase/Three phase 220V 50/60Hz | |
Voltage Range | 220V:170V~240V 380V:330~440V | ||
Output | Voltage Range | 220V:0~220V 380V:0~380V | |
Frequency Range | 0.10`400.00Hz | ||
Control method | V/F control, Space vector control. | ||
Indication | Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. | ||
Control Specifications | Output Frequency Range | 0.10Hz~400.00Hz | |
Frequency Setting Resolution | Digital input:0.01Hz, analog input:0.1% of maximum output frequency | ||
Output Frequency Accuracy | 0.01Hz | ||
V/F Control | Setting V/F curve to satisfy various load requirements | ||
Torque Control | Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque | ||
Multifunctional lnput Terminal |
Six multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions | ||
Multifunctional Output Terminal |
2 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings | ||
Acceleration/deceleration Time Setting | 0~-999.9s acceleration/deceleration time can be set individually | ||
PID Control | Built-in PID control | ||
RS485 | Standard RS485 communication function(MODBUS) | ||
Frequency Setting | Analog input:0 to 10V,,0 to 20mA can be selected; Dig ital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN |
||
Multi-speed | Six multifunction input terminals, 15section speed can be set | ||
Automatic voltage regulation | Automatic voltage regulation function can be selected | ||
Counter | Built -in 2group of counters | ||
Protection/ Warning Function |
Overload | 150%,60 second(Constant torque) | |
Over Voltage | Over voltage protection can be set | ||
Under Voltage | Under voltage protection can be set | ||
Other Protections | Overheat, short circuit, over current, and parameter lock and so on | ||
ronment | Ambient Temperature | -10ºC to 40ºC(non-freezing) | |
Ambient Humidity | Max.95%(non-condensing) | ||
Altitude | Lower than 1000m | ||
Vibration | Max. 0.5G | ||
Structure | Cooling Mode | Forced air cooling | |
Protective Structure | IP20 | ||
Installation | Mode | Wall Mounted | |
Model | Rate output power (KW) |
Capacity (KVA) |
Current output (A) |
Overload capacity (A) |
Application motor (KW) |
1PH AC220V,50/60HZ | |||||
S900-2S0.4GS | 0.4 | 1.0 | 2.2 | 3.75 | 0.4 |
S900-2S0.75GS | 0.75 | 2.0 | 5.0 | 7.5 | 0.75 |
S900-2S1.5GS | 1.5 | 2.8 | 7.0 | 10.5 | 1.5 |
3PH AC380V ,50/60Hz | |||||
S900-4T0.75GS | 0.75 | 2.2 | 2.7 | 4.05 | 0.75 |
S900-4T1.5GS | 1.5 | 3.2 | 4.0 | 6.0 | 1.5 |
S900-4T2.2GS | 2.2 | 4.0 | 5.0 | 7.5 | 2.2 |
S900-4T3.7GS | 3.7 | 6.8 | 8.6 | 12.9 | 3.7 |
S900-4T5.5GS | 5.5 | 10 | 12.5 | 18.75 | 5.5 |
S900-4T7.5GS | 7.35 | 14 | 17.5 | 21 | 7.5 |
S900-4T11GS | 11 | 19 | 24 | 36 | 11 |
S900-4T15GS | 15 | 26 | 33 | 45 | 15 |
S900-4T18.5GS | 18.5 | 32 | 40 | 60 | 18.5 |
S900-4T22GS | 22 | 37 | 47 | 70.5 | 22 |
S900-4T30GS | 30 | 52 | 65 | 97.5 | 30 |
S900-4T37GS | 37 | 64 | 80 | 120 | 37 |