0.75kw VFD, AC Drive, Frequency Inverter up to 315kw

Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Principle of Work: Vector Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Current
Voltage of Power Supply: Medium Voltage Variable-Frequency Drive
Customization:

Contact Supplier

Gold Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
Z900
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Constant Torque Universal Type
Brand
Machtric
Output Frequency Range
0~400Hz
Brand Name
Machtric
Power Range
220V(0.4~3.7kw)380V(0.75~315kw)
Protection
Overload
Control Made
Open Loop Vector Control
Jog Control
Jog Frequency Range:0~50Hz
Certificate
Ce,ISO9001
Color
OEM
Protective Structure
IP20
Warranty
12 Months
Transport Package
Export Standard Package
Specification
CE/ISO9001
Trademark
machtric
Origin
China
HS Code
850440999
Production Capacity
50000 PCS/Year

Product Description


0.75kw VFD, AC Drive, Frequency Inverter up to 315kw
1.compact,general use. Widely used in crane.

2.open loop vector control.

3.One phase  220v  0.4~3.7kw     three phase  380v 0.75~315kw


4. Is one of the most fire we sell. 
 

Technical Specifications:
 
Item  
Standard
functions
 
Control mode Sensorless flux vector control (SFVC)
Voltage/Frequency (V/F) control
Maximum frequency Vector control: 0-300 Hz
V/F control: 0-3200Hz
Carrier frequency 1 kHz-16 kHz
The carrier frequency can be automatically adjusted based on the load features.
 
Input frequency resolution
 
 
Dgital setting: 0.01 Hz
Analog setting: maximum frequency x 0.025%
 
Startup torque G type: 0.5 Hz/150% (SFVC);
P type: 0.5 Hz/100%
Speed range
 
1:100 (SFVC)
 
Speed stability accuracy ± 0.5% (SFVC)
 
Overload capacity G type: 60s for 150% of the rated current,
 3s for 180% of the rated current.
P type: 60s for 120% of the rated current,
3s for 150% of the rated current.
Torque boost Auto-boost
Customized boost 0.1%-30.0%
V/F  curve
 
Liner V/F  curve
Multi-point V/F  curve
N-power V/F curve (1.2-power, 1.4-power, 1.6-power,
1.8-power, square)
V/F  separation Two types: complete separation; half separation
Ramp mode
 
Straight-line ramp
S-curve ramp
Four groups of acceleration/deceleration time with the range of 0.0-6500.0s
DC braking DC braking frequency: 0.00 Hz to maximum frequency
Braking time: 0.0-36.0s
Braking action current value: 0.0%-100.0%
JOG control
 
JOG frequency range: 0.00-50.00 Hz
JOG acceleration/deceleration time: 0.0-6500.0s
     Item Z900
Standard
functions
Multiple preset speeds It implements up to 16 speeds via the simple PLC function or by input(X) terminal states
Built-in PID It realizes process-controlled closed loop control system easily.
Auto voltage
regulation (AVR)
It can keep constant output voltage automatically when the mains voltage changes.
Over-voltage/
Over-current stall
control
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to
over-voltage/over-current.
Torque limit and torque
control
It can limit the torque automatically and prevent frequent over-current tripping during the running process.
Power dip ride through The load feedback energy compensates the voltage
reduction so that the AC drive can continue to run for a
short time.
Rapid current limit It helps to avoid frequent over-current faults of the AC drive.
High performance high-performance current vector
control technology.
Timing control Time range: 0.0-6500.0 minutes
Communication methods RS485
Protection mode Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage
protection, under voltage protection, overheat protection and overload protection.
Input and output Input terminal 6 digital input terminals, one of which supports up to 100 kHz high-speed pulse input.
1 analog input terminals, switchable between  0-10 V input and 4-20 mA input.
Frequency source Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting.
Auxiliary frequency source There are ten auxiliary frequency sources.It can implement
fine tuning of auxiliary frequency and frequency synthesis.
Running command source Operation panel/Control terminals/Serial communication port
You can perform switchover between these sources in various ways.
Output terminal 1 digital output terminal
1 relay output terminal
1 analog output terminal :that supports 0-20 mA current output or 0-10 V voltage output
Item Z900
operation on
the operation
panel
LED display It displays the parameters.
Key locking and
function selection
It can lock the keys partially or completely and define the
function range of some keys so as to prevent mis-function.
Environment Installation location Indoor, free from direct sunlight, dust, corrosive gas,
combustible gas, oil fog, steam, drip or salt.
Altitude Lower than 1000 m
Ambient temperature  -10°C ~40°C (de-rated if the ambient temperature is
 between 40°C and 50°C)
Humidity Less than 95%RH, without condensing
Vibration Less than 5.9 m/s2 (0.6 g)
Storage temperature  -20°C~60°C
 
 Control terminals :

0.75kw VFD, AC Drive, Frequency Inverter up to 315kw


Package:export standard package.

Delivery time: 7 weekdays after get the payment.

Delivery mode: Ocean shipping, Air transport, Express delivery/( Choose by the customer).
Payment terms: L/C/ T/T / Western Union  /  MoneyGram.


    Factory:
0.75kw VFD, AC Drive, Frequency Inverter up to 315kw


About us:

Our products have been broadly applied in Textile, Packing, Plastic, Ceramic, Traffic, Building, Metallurgy, Chemical industry, Light industry, Military industry etc various industry equipment.




We also have other frequency inverter. If you have any questions, please don't hesitate contact with me.


Wendy


TEL:86-18850877082
 
 
  


 

Send your message to this supplier

*From:
*To:
avatar Ms. Ivy Shao
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now