Customization: | Available |
---|---|
Application: | High Frequency Converter Transducer, General Purpose Application |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
COMPANY ADVANTAGE
- Qualified inverter supplier for Fuji Electric (Japan)
- 10 years OEM/ODM Experience
- Manufacture in this field for almost 20 years experience.
- Reasonable price and punctual delivery time
- 70 R & D personnel have many years experience
- Received the National Invention Award
Major Customers
- Fuji Electric
- Jeltron System PVT
- Senterno Sas
- Sinar Surya
- Electric Otomyson
Variable frequency inverters
Specifications:
1) Rated voltage: 220V / single phase, 220V / three phase, 440V / three phase
2) Power range: 0.75 ~ 22kW
3) Output frequency: 0.1 ~ 400Hz
Features:
1) High-performance low-noise
2) Automatic torque compensation
3) RS-485 in-line interface build-in
4) 2-level accelerating / decelerating time
5) Automatic slip compensation, automatic voltage regulation (AVR)
6) 8-level preset table speed
7) Restart after instantaneous power-off
8) All-dimensional protection
S1100 Series Inverter
More professional control program
Professionally customized core computing program,Smooth shift on forward and reverse rotaion,Automatic torque compensation,Automatic slip compensation.
Lower heat
Advanced control technology of switching 3-phase to 2-phase,reduces heat by 33.3%.
More excellence performance
A variety of customized functions bring maximum benefits and convenience to users.
Specification
Items |
S1100 E |
||
Power Supply |
Rated voltage, Frequency |
Single phase/Three phase 220V 50/60Hz Single-phase 220V 50/60Hz |
|
Voltage Range |
220V: 170V~240V; 220V: 170V~240V |
||
Output |
Voltage Range |
220V: 0~220V; 220V: 0~240V |
|
Frequency Range |
0.10`400.00Hz |
||
Control method |
V/F control, Space vector control. |
||
Indication |
Operating status/Alarm definition/interactive guidance: eg, frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. |
||
Control Specifications |
Output Frequency Range |
0.10Hz~400.00Hz |
|
Frequency Setting Resolution |
Digital input: 0.01Hz, analog input: 0.1% of maximum output frequency |
||
Output Frequency Accuracy |
0.01Hz |
||
V/F Control |
Setting V/F curve to satisfy various load requirements |
||
Torque Control |
Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque |
||
Multifunctional Input Terminal |
Eight multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions |
||
Multifunctional Output Terminal |
3 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings |
||
Acceleration/deceleration time Setting |
0~-6000s acceleration/deceleration time can be set individually |
||
Other Functions |
PID Control |
Built-in PID control |
|
RS485 |
Standard RS485 communication function(MODBUS) |
||
Frequency Setting |
Analog input: 0 to 10V, , 0 to 20mA can be selected; Digital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN |
||
Multi-speed |
Eight multifunction input terminals, 15section speed can be set |
||
Automatic voltage regulation |
Automatic voltage regulation function can be selected |
||
Counter |
Built – in 2group of counters |
||
Protection/ Warning Function |
Overload |
150%, 60 second(Constant torque); 120%. 60 second (variable torque) |
|
Over Voltage |
Over voltage protection can be set |
||
Under Voltage |
Under voltage protection can be set |
||
Other Protections |
Overheat, short circuit, over current, and parameter lock and so on |
||
Environment |
Ambient Temperature |
-10 ° C to 40 ° C (non-freezing) |
|
Ambient Humidity |
Max. 95%(non-condensing) |
||
Altitude |
Lower than 1000m |
||
Vibration |
Max. 0.5G |
||
Structure |
Cooling Mode |
Forced air cooling |
|
Protective Structure |
IP20 |
||
Installation |
Mode |
Below 90KW: Wall Mounted; 110~200KW: Wall Mounted or in Cabinet; Above 220KW: in Cabinet |