Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Tripe Phase |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item |
S3800E |
|
Based functions |
Control mode |
V/F(Voltage/Frequency) control |
Sensorless flux vector control (VC) |
||
Closed-loop vector control (CVC) |
||
Maximum frequency |
Vector control: 0-320 Hz |
|
V/F control: 0-3200Hz |
||
Carrier frequency |
1.0-16.0 kHz |
|
The carrier frequency is automatically adjusted based on the load features. |
||
Input frequency esolution |
Dgital setting: 0.01 Hz |
|
Analog setting: 0.025% of maximum frequency |
||
Startup torque |
G type: 0.5 Hz/150% (VC); 0 Hz/180% (CVC) |
|
P type: 0.5 Hz/100% |
||
Speed range |
1:100 (VC) |
|
1:1000 (CVC) |
||
Speed stability accuracy |
± 0.2% (VC) |
|
± 0.02% (CVC) |
||
Torque control accuracy |
± 5% (CVC) |
|
Overload capacity |
G type: 60s for 150% of the rated current, 3s for 180% of the rated current. |
|
P type: 60s for 120% of the rated current, 3s for 150% of the rated current. |
||
Torque boost |
Auto boost |
|
Customized boost 0.1%-30.0% |
||
V/F curve |
Line V/F curve |
|
Multi-point V/F curve |
||
N-power V/F curve (1.2-power, 1.4-power, 1.6-power,1.8-power, square) |
||
V/F separation |
two types: complete separation; half separation |
|
Ramp mode |
Straight-line ramp |
|
S-curve ramp |
||
Four groups of acceleration/deceleration time with the range of 0.0-6500.0s |
||
DC braking |
DC braking frequency: 0.00 Hz to maximum frequency |
|
Braking time: 0.0-100.0s |
||
Braking action current value: 0.0%-100.0% |
||
JOG control |
JOG frequency range: 0.00-50.00 Hz |
|
JOG acceleration/deceleration time: 0.0-6500.0s |
||
Onboard multiple preset speeds |
It implements up to 16 speeds via the simple PLC function or combination of terminal states |
|
Onboard PID |
It realizes process-controlled closed loop control system easily. |
|
Auto voltage |
It can keep constant output voltage automatically when the mains voltage changes. |
|
regulation (AVR) |
||
Overvoltage/ Overcurrent stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current. |
|
Torque limit and control |
It can limit the torque automatically and prevent frequent over current tripping during the running process.Torque control can be implemented in the CVC mode. |
|
Individualized functions |
Support for multiple PG card |
Support for rotating transformer PG card,differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card |
Power dip ride through |
The load feedback energy compensates the voltage |
|
reduction so that the AC drive can continue to run for a |
||
short time. |
||
Rapid current limit |
It helps to avoid frequent over current faults of the AC drive. |
|
High performance |
Control of asynchronous motor and synchronous motor are |
|
implemented through the high-performance current vector |
||
control technology. |
||
Timing control |
Time range: 0.0-6500.0 minutes |
|
Communication methods |
MODBUS-RTU,PROFIBUS-DP,CAN |
|
Protection mode |
Motor short-circuit detection at power-on, input/output |
|
phase loss protection, over current protection, overvoltage |
||
protection, under voltage protection, overheat protection and overload protection. |
||
Input and output |
Input terminal |
8 digital input terminals, one of which supports up to |
100 kHz high-speed pulse input. |
||
2 analog input terminals, one of which only supports |
||
0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input. |
||
Frequency source |
Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. |
|
Auxiliary frequency source |
There are ten auxiliary frequency sources.It can implement |
|
fine tuning of auxiliary frequency and frequency synthesis. |
||
Running command source |
Operation panel/Control terminals/Serial communication port |
|
You can perform switchover between these sources in |
||
various ways. |
||
Output terminal |
1 high-speed pulse output terminal (open-collector) that |
|
supports 0-100 kHz square wave signal output |
||
1 digital output terminal |
||
2 relay output terminal |
||
2 analog output terminal :that supports 0-20 mA current output or 0-10 V voltage output |
||
operation on the operation panel |
LED display |
It displays the parameters. |
Key locking and |
It can lock the keys partially or completely and define the |
|
function selection |
function range of some keys so as to prevent mis-function. |
|
Optional parts |
Rotating transformer PG card,differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card |
|
Environment |
Installation location |
Indoor, free from direct sunlight, dust, corrosive gas, |
combustible gas, oil smoke, vapour, drip or salt. |
||
Altitude |
Lower than 1000 m |
|
Ambient temperature |
-10°C ~40°C (de-rated if the ambient temperature is |
|
between 40°C and 50°C) |
||
Humidity |
Less than 95%RH, without condensing |
|
Vibration |
Less than 5.9 m/s2 (0.6 g) |
|
Storage temperature |
-20°C~60°C |