1.5kw 380V 50/60Hz 3 Phase Frequency Inverter

Application: High Frequency Converter Transducer
Output Type: Single/Three Phases
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company

Basic Info.

Model NO.
S1100E inverter
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Constant Torque Universal Type
Brand
Sanch
Color
White
ISO 9001,ISO14001,Ohsas18001 & CE
Customized Specification Is Accepted
10 Years OEM/ODM Experience
70 R & D Personnel Have Many Years Experience
Received The National Invention Award
Many Machine Lines and Output Is 10000set /Month
5000 Piece/Pieces / Month
Exported Packing Standard
Frequency Converter(CE)
Variable Speed Drive
Frequency Inverter
VFD
Transport Package
Polyfoam Packing First,Then Standard Export Carton
Specification
ISO 9001, ISO14001, OHSAS18001 & CE
Trademark
Sanch
Origin
China
HS Code
850440999
Production Capacity
50000 PCS /Year

Product Description

Variable frequency inverters

High torque
Superior performance
Low noise, mini size
Adopting the latest generation
IGBT technology

1 Reliability
2 Lower heat
3 High performance
4 Faster computing speed
5 More excellence performance

Used in fan and pump, lift
High torque, superior performance
Low noise, mini size
Adopting the latest generation IGBT tech
Product Description
Variable frequency inverters
Specifications:
1) Rated voltage: 220V / single phase, 220V / three phase, 440V / three phase
2) Power range: 0.75 ~ 22kW
3) Output frequency: 1.0 ~ 400Hz

Features:
1) High-performance low-noise
2) Automatic torque compensation
3) RS-485 in-line interface build-in
4) 2-level accelerating / decelerating time
5) Automatic slip compensation, automatic voltage regulation (AVR)
6) 8-level preset table speed
7) Restart after instantaneous power-off
8) All-dimensional protection

S1100 Series Inverter
More professional control program
Professionally customized core computing program, Smooth shift on forward and reverse rotaion, Automatic torque compensation, Automatic slip compensation.
Lower heat
Advanced control technology of switching 3-phase to 2-phase, reduces heat by 33.3%.
Faster computing speed
Adopting nanometer manufacturing technology, CPU with built-in dual core makes the computing speed dramatically improve.
More excellence performance
A variety of customized functions bring maximum benefits and convenience to users.

Reliability
· Protect function: Over voltage(OU), low voltage(LU), over current(OC), over heat(OH), over load(OL)
· Over voltage and over current stall prevention
· The technology of integration hardware and software wave filtering for better anti-jamming effects
· 3-level prohibited frequencies can avoid resonance effectively
· Braking using software control, be able to adjust brake-bit and brake occupating coefficient

High performance
· Automatic torque compensation-start torque can be up to 150% at 2Hz
· Aautomtic slip compensation-more accurate speed
· Ultra-low noise-motor runs more stably
· High overload capacity-150% rated torque can last for 65 senconds

Multi-function
· PID feedback control
· Oscillation frequency function
· Built-in PLC enables 16-level speed program running
· Multifarious frequency input methods: Pules input, AVI/ACI superimposed, UP/DOWN, RS-485 and so on.
· Multifarious control methods: Operation control, exterior terminal two-line/three-line control, RS-485 control.
· Multifarious stop methods(OFF stop, stop for AVI zero)
· Multifarious input methods: External EF, couting input, frequency switching, Pendulum frequency input and so on.
· Multifarious output methods: Multi-function relay output, multifunction collector open circuit output
Multifarious output methods: Indication of forward and reverse rotation, counting arrival, program
· Operation, and faults.
Other functions: Power failure memory, running-locked when power on, automatic voltage
· Regulation(AVR), DC brake, password protection

S1100 Series catalog:
S1100 Series manual:

Variable Frequency Converter, Frequency Converter(CE), CE approved frequency converter 60Hz 50Hz,
Quanzhou Machtric Automation Equipment Co., Ltd
Mobile: 0086 15060807366
Tel: 86 0595-22555211-804
Fax: 86 0595-22555211-803
Input Voltage 220V 440V
Model number: S1100-2T/4T***G 0.75 1.5 2.2 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
Output Applicable motor power (KW) 0.75 1.5 2.2 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
Output rated current (A) 5 6.5 11 3.0 4.2 5.5 8.2 13 18 24 32 38 45
Max output voltage (A) Input power
Over load capacity 150% of rated output current and run for 65 seconds
Power Phase. Voltage. Frequency 1-phase/3-phase 200-240V 50/60HZ 3-phase 380-460V 50/60HZ
Allowable variation range of Voltage Frequency Voltage: ± 15%  Frequency: ± 5%
Input current (A) 11/7.4 15/10 27/15 4.2 6.0 7.2 8.5 14 20.6 28 30 39 49
Controlling Characteristics Control mode Adopting SVPWM modulating techniques (V/F control and Speed Sensor-less Vector)
Output range of frequency 0.01~400.0Hz
Frequency setting analyzing degree 0.01Hz
Output frequency analyzing degree 0.01Hz
PWM load wave frequency Available to modulate from 2 to 10kHz
Torque increase Auto torque-increase and auto slip compensation at 2 Hz the starting torque can reach 150% of rated torque.
Jog frequency 3 points can be set from 0.01 to 400.0Hz
Acceleration/deceleration time 0.01 to 600.0 seconds. (2 steps of accel/decel time can be set separately. )
Stall Prevention Level According to the load characteristics of motor, it' s available to be set as 50 to 200% of the rated current of the drive
DC braking Available to be operated from 0.01 to 400.0 Hz from STOP, braking 0 to 100% of the rated current. Starting time 0.0 to-60.0 sec, Stopping time 0.0-60.0 sec
Braking torque 20% (125% shall be available if connected with purchase braking resistor externally)          (or 1 to 25HP, equipped within the electric crystals, for 30 HP, braking unit module shall be connected externally. )
V/F curve V/F curve available to be set
Operation characteristics Frequency setting signal Digital Operator Set by UP and DOWN
External terminals 0-10VDC, 4-20mADC, Series Communication Board (RS-485)
Running operatisignal Digital Operator Available to be operated by RUN, STOP and JOG keys.
External terminals 2 wire styles (Fwd/Stop, Rev/Stop, Run/Stop and Fed/Rev) /3 wire operation, JOG running, Serial Communication Board(RS-485)
Intelligent Input Terminal Switching of 16 step pre-set available speed; Switching of First/Second acceleration/deceleration time; prohibiting acceleration/deceleration and external interrupt input; Jog running UP/DOWN frequency terminal setting; Count terminals
Intelligent Output Terminal During running, frequency agreement output, non-zero count agreement output, over torque output, external interrupt reference. Low voltage detection, operation mode reference, fault output and external fault interruption.
Analog signal output Correspond to actual output frequency or output current.
Fault signal contact Contact of ON at AC motor drive (Relay with one C contact or two open collector output. )
Built-in Function Setting max/min output frequency; momentary power off restarting; fault restaring; setting of S curve acceleration/deceleration time; auto-voltage stabilizing output modulation; digital frequency output signal; fault records; parameters locking; reset to factory setting; inhibiting reverse run; over current stalling prevention, over voltage stalling prevention, electrical thermal relay.
Protection Function Over current; over voltage, low voltage; external fault interruption input; motor over load; GFF: grounding protection(For optional use); over load of the drive and drive overheating
Digital operator Consisting of 8 functional keys, 7 step LED in 5 digits; 5 status LED indicators. Available to set frequency, display actual output frequency, output current, self-determined unit parameter overview of users, modify settings and for parameter locking, fault displaying. Available to perform running, stop, reset, fwd/rev run and jog run.
Environment Operational Environment temperature -10° C to +50° C (+40° C ~ +50° C available when the dust cover is removed)
Storing temperature -20° C to + 60° C
Installation height Lower than 1000m, without corrosive gas, fluid and dust.
Vibration Below 20Hz 9.80665m/s² (1g), 20~50 Hz 5.88m/s² (0.6g)
Protection degrees Determined by the installation environment of the end-users.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2010

Suppliers with verified business licenses

Rating: 5.0/5
Trading Company
Registered Capital
73901.09 USD
Management System Certification
ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001