Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | 1/3 Phase |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items |
S800E |
||
Output |
Voltage Range |
220V: 187v-253v 380V: 323v-440v |
|
Frequency Range |
0.10~400.00Hz |
||
Control method |
V/F control, Space vector control. |
||
Indication |
Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/ current, DC bus voltage, the temperature and so on. |
||
Control SpeciAlations |
Output Frequency Range |
0.10Hz~400.00Hz |
|
Frequency Setting Resolution |
Digital input: 0.01Hz, analog input: 0.1% of maximum output frequency |
||
Output Frequency Accuracy |
0.01Hz |
||
V/F Control |
Setting V/F curve to satisfy various load Requirements. |
||
Torque Control |
Auto increase: auto raise torque by loading Condition; Manual increase: enable to set 0.0~20.0% of raising torque. |
||
Multifunctional Input Terminal |
Four multi-function input terminals, realizing functions including fifteen section speed control, Program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions |
||
Multifunctional Output Terminal |
1 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other Information and warnings. |
||
Acceleration/ deceleration Time Setting |
0~999.9s acceleration/deceleration time can be set individually. |
||
Other functions |
PID Control |
Built-in PID control |
|
RS485 |
Standard RS485 communication function(MODBUS) |
||
Frequency Setting |
Analog input: 0 to 10 V, 0 to 20mA can be selected; Digital input:Input using the setting dial of the operation panel or RS485 or UP/DOWN. Note:AVI terminals can be used to select an analog voltage input(AV) and analog current input(AI) through the switch J2. Note: AVI terminals can be used to select an Analog voltage input (AV) and analog current Input(AI) through the switch J2. |
||
Multi-speed |
Four multifunction input terminals, 15 section speed can be set |
||
Automatic voltage ID ControlliAlation regulation |
Automatic voltage regulation function can be Selected |
||
Counter |
Built-in 2 group of counters |
||
Protection/Warning Function |
Overload |
150%, 60 second(Constant torque) |
|
Over Voltage |
Over voltage protection can be set. |
||
Under Voltage |
Under voltage protection can be set |
||
Other Protections |
Overheat,output short circuit,over current, and Parameter lock and so on. |
||
Environment |
Ambient Temperature |
-10ºC to 40ºC(non-freezing) |
|
Ambient Humidity |
Max. 95% (non-condensing) |
||
Altitude |
Lower than 1000m |
||
Vibration |
Max.0.5G |
||
Structure |
Cooling Mode |
Forced air cooling |
|
Protective Structure |
IP 20 |
||
Installation |
Mode |
Wall-mounted or standard 35MM rail mounting |
Model |
Input | Power Output (KW) |
Capacity (KVA) |
Current Output (A) |
Load Capacity (60s)(A) |
Motor Equipped (KW) |
S800-2T0.4GE | 1PH/3PH 220V- 50/60HZ |
0.4 | 1.0 | 2.5 | 3.75 | 0.4 |
S800-2T0.75GE | 0.75 | 2.0 | 5.0 | 7.50 | 0.75 | |
S800-2T1.5GE | 1.5 | 2.8 | 7.0 | 10.50 | 1.5 |