Items | S2100 E | |||||
Power Supply |
Rated voltage, Frequency | Single phase/Three phase 220V 50/60Hz Single-phase 220V 50/60Hz | ||||
Voltage Range | 380V: 330V~440V; 220V: 170V~240V | |||||
Output | Voltage Range | 380V: 0~380V; 220V: 0~220V | ||||
Frequency Range | 0.10`400.00Hz | |||||
Control method | V/F control, Space vector control. | |||||
Indication | Operating status/Alarm definition/interactive guidance: eg, frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. | |||||
Control Specifications | Output Frequency Range | 0.10Hz~400.00Hz | ||||
Frequency Setting Resolution | Digital input: 0.01Hz, analog input: 0.1% of maximum output frequency | |||||
Output Frequency Accuracy | 0.01Hz | |||||
V/F Control | Setting V/F curve to satisfy various load requirements | |||||
Torque Control | Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque | |||||
Multifunctional Input Terminal |
Eight multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions | |||||
Multifunctional Output Terminal |
3 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings | |||||
Acceleration/deceleration time Setting | 0~-6000s acceleration/deceleration time can be set individually | |||||
Items | S2100 E | S2100 E | ||||
Other Functions | PID Control | Built-in PID control | ||||
RS485 | Standard RS485 communication function(MODBUS) | |||||
Frequency Setting | Analog input: 0 to 10V, , 0 to 20mA can be selected; z Digital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN |
|||||
Multi-speed | Eight multifunction input terminals, 15section speed can be set | |||||
Automatic voltage regulation | Automatic voltage regulation function can be selected | |||||
Counter | Built - in 2group of counters | |||||
Protection/ Warning Function |
Overload | 150%, 60 second(Constant torque); 120%. 60 second (variable torque) | ||||
Over Voltage | Over voltage protection can be set | |||||
Under Voltage | Under voltage protection can be set | |||||
Other Protections | Overheat, short circuit, over current, and parameter lock and so on | |||||
Environment | Ambient Temperature | -10to 40(non-freezing) | ||||
Ambient Humidity | Max. 95%(non-condensing) | |||||
Altitude | Lower than 1000m | |||||
Vibration | Max. 0.5G | |||||
Structure | Cooling Mode | Forced air cooling | ||||
Protective Structure | IP20 | |||||