Main Specification:
Items |
S800E |
|
Power Supply |
Rated voltage, Frequency |
One-phase/Three-phase AC 220V 50/60Hz |
Voltage Range |
220V: 170~240V |
|
Output |
Voltage Range |
220V: 0~220V |
Frequency Range |
0.10~400.00Hz |
|
Control method |
V/F control, Space vector control. |
|
Indication |
Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/ current, DC bus voltage, the temperature and so on. |
|
Control SpeciAlations |
Output Frequency Range |
0.10Hz~400.00Hz |
Frequency Setting Resolution |
Digital input: 0.01Hz, analog input: 0.1% of maximum output frequency |
|
Output Frequency Accuracy |
0.01Hz |
|
V/F Control |
Setting V/F curve to satisfy various load Requirements. |
|
Torque Control |
Auto increase: auto raise torque by loading Condition; Manual increase: enable to set 0.0~20.0% of raising torque. |
|
Multifunctional Input Terminal |
Four multi-function input terminals, realizing functions including fifteen section speed control, Program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions |
|
Multifunctional Output Terminal |
1 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other Information and warnings. |
|
Acceleration/ deceleration Time Setting |
0~999.9s acceleration/deceleration time can be set individually. |
|
Other functions |
PID Control |
Built-in PID control |
RS485 |
Standard RS485 communication function(MODBUS) |
|
Frequency Setting |
Analog input: 0 to 10 V, 0 to 20mA can be selected; Digital input:Input using the setting dial of the operation panel or RS485 or UP/DOWN. Note:AVI terminals can be used to select an analog voltage input(AV) and analog current input(AI) through the switch J2. Note: AVI terminals can be used to select an Analog voltage input (AV) and analog current Input(AI) through the switch J2. |
|
Multi-speed |
Four multifunction input terminals, 15 section speed can be set |
|
Automatic voltage ID ControlliAlation regulation |
Automatic voltage regulation function can be Selected |
|
Counter |
Built-in 2 group of counters |
|
Protection/Warning Function |
Overload |
150%, 60 second(Constant torque) |
Over Voltage |
Over voltage protection can be set. |
|
Under Voltage |
Under voltage protection can be set |
|
Other Protections |
Overheat,output short circuit,over current, and Parameter lock and so on. |
|
Environment |
Ambient Temperature |
-10ºC to 40ºC(non-freezing) |
Ambient Humidity |
Max. 95% (non-condensing) |
|
Altitude |
Lower than 1000m |
|
Vibration |
Max.0.5G |
|
Structure |
Cooling Mode |
Forced air cooling |
Protective Structure |
IP 20 |
|
Installation |
Mode |
Wall-mounted or standard 35MM rail mounting |
Model |
Input |
Power Output (KW) |
Capacity (KVA) |
Current Output (A) |
Load Capacity (60s)(A) |
Motor Equipped (KW) |
S800-2T0.4GE |
1PH/3PH 220V- 50/60HZ |
0.4 |
1.0 |
2.5 |
3.75 |
0.4 |
S800-2T0.75GE |
0.75 |
2.0 |
5.0 |
7.50 |
0.75 |
|
S800-2T1.5GE |
1.5 |
2.8 |
7.0 |
10.50 |
1.5 |