Frequency Inverter for General Purpose

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: 1/3 Phase
Gold Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 5 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (10)
  • Frequency Inverter for General Purpose
  • Frequency Inverter for General Purpose
Find Similar Products

Basic Info.

Model NO.
S1100VG
Principle of Work
Vector Control Transducer
Switch Mode
Open Loop Vector Control
Main Circuit Type
Current
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Simple Type, Elevator Special, Textile Special, Constant Torque Universal Type
Brand
Machtric
Control Mode
V/F Control, Vector
out Frequency
0.01~400.0Hz
Output Frequency Range
50Hz /60Hz
Output Power
0.4kw-250kw
Communicate
RS485
Output Phase
1/3 Phase
Input Phase
1/3 Phase
Color
Black
Working Environment
-20 - 60 Degree
Transport Package
Standard Export Package
Specification
CE, ISO9001
Trademark
Machtric
Origin
China
Production Capacity
10000/Months

Product Description

S1100V Specification
Item Specifications












Basic function
Maximum frequency 400Hz
Carrier Frequency 1k to 15kHz;The carrier frequency will be automatically
Adjusted according to the load characteristics.
Input frequency
Resolution
Digital setting:0.01Hz
Analog setting:Maximum frequency ×0.1%
Control mode V/F control
Vector flux control 1
Vector flux control 2
Startup torque G modle:0.5Hz/180%(Open loop Vector flux control)
P model:0.5Hz/120%(Open loop Vector flux control)
Speed adjustment
Range
1:200(Open loop Vector flux control)
Speed stabilization
Precision
Open loop Vector flux control:≤±0.5%
Speed stabilization
Precision
Open loop Vector flux control:≤±0.3%
Torque response ≤40ms(Open magnetic flux vector control)
Overload capacity G model:150% rated current 60s;180% rated current 3s
P model:130% rated current 60s;150% rated current 3s
Torque hoist Automatic torque hoist;Manual torque hoist 0.1% to
30.0%
V/F curve Linear V/F, Multi-point V/F, and Square V/F
Speed-up and
Speed-down curve
Straight line or S curve speed-up and speed-down
Mode;Two kinds of speed-up and speed-down
Time;Speed-up and speed-down time ranges between 0.0s
To 3000.0min.
DC brake DC brake frequency:0.00Hz to maximum frequency;Brake time:0.0s to 36.0s,and brake current value:0.0% to 100.0%.
Jog control Jog frequency range:0.00Hz to 50.00Hz;Jog
Speed-up/speed-down time:0.0s to 3000.0s.
Simple PLC and MS speed running It can realize a maximum of 16 segments speed running
Via the built-in PLC or control terminal.
Built-in PID It is easy to realize process-controlled close loop control
System.
(AVR)Auto
Voltage regulation
It can keep constant output voltage automatically in case of change of mains voltage.
Torque limit and control "Shovel" characteristics, the runtime automatic torquelimit, prevent frequent over-current trip;Closed loop vectormodel can realize the torque control
Individua-lized function Peripherals self-detection upon
Power-on
It can conduct safety detections on the peripherals upon power-on, including earth and short circuit detections.
Shared DC bus
Function
It can realize the function that multiple inverters share the DC bus.
JOG key Programmable key:Select the command channel switching/forward and reverse rotations/jog operation.
Textile swing
Frequency control
Multiple triangular-wave frequency control function.
CBC Function Built-CBC algorithm to reduce the probability of voer-current converter reported to improve the whole anti-jamming capabitity.
Timing control Timing control function:Setting time range between 0h to 65535h.
Keyboard extension line standard Customers can use standard cable extensionon the keyboard
Run Running command
Channel
Three types of channels:Operation panel reference,control
Terminal reference and serial communication port
Reference.These channels can be switched in various
Modes.
Frequency source There are totally ten types of frequency sources, such as
Digital reference, analog voltage reference, analog current
Reference, MS speed, PLC, PID, and serial port reference.
Auxiliary frequency
Source
There are ten types of auxiliary frequency sources.It can
Implement micro tuning and synthesis of auxiliary
Frequency.
Input terminal There are five digital input terminals.It can be compatible with active PNP or NPN input mode.
There are two analog input terminals,one of which can be used only as voltage input,while the other can be used as voltage or current input.(It can expand one voltage  input terminal)
Output terminal One digital output terminal
One relay output terminal
One analog output terminal,with optional 0/4mA to 20mA or 0/2V to 10V.It can realize the output of such physical parameters as setting  frequency and output frequency.
Display
And
Keyboard
Operation
LED display The machine has the LED keyboard,and realize parameter settings,status monitoring function.
LCD display Optional, / English prompts content
Parameter Copy Keyboard can be copied using the parameters to achive the rapid replication parameter.
Keylock and function selection The realization of key part or all of the lock, define the scope of the keys, to prevent misoperation
 
Others Protection
Function
It can implement power-on motor short-circuit detection,
Input/output phase loss protection, over current protection,
Over voltage protection, under voltage protection, overheating protection and overload protection.
Accessories LCD Operation Panel,Brake Uint.
Environment Using place Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.
Altitude 1000m, derated when above 1000m
Ambient
Temperature
-10 ºC Celsius to +40 ºC Celsius (Derated when used in
The ambient temperature of 40 ºC Celsius to 50 ºC
Celsius)
Humidity Less than 95%RH, without condensing
Vibration Less than 5.9 m/s2(0.6g)
Storage temperature -20 Celsius to +60 Celsius
Class of pollution 2
Products
Standard
Product implementation of safety standards IEC61800-5-1:2007
Implementation of EMC standard IEC61800-5-1:2007

Mounting Hole Dimensions of S1100V Series Inverter (mm)
Model Mounting
Hole
Physical Dimension Diameter of
Mounting Hole (mm)
A (mm) B (mm) H (mm) W (mm) D (mm)  
S1100VG-2S0.4GEB 135 207 223 148 159 φ5.4
S1100VG-2S0.75GEB
S1100VG-2S1.5GEB
S1100VG-2S2.2GEB
S1100VG-4T0.75GEB/1.5PEB
S1100VG-4T1.5GEB/2.2PEB
S1100VG-4T2.2GEB/4.0PEB
S1100VG-4T4.0GEB/5.5PEB
S1100VG-4T5.5GEB/7.5PEB 150 226 238 162 165 φ5.4
S1100VG-4T7.5GEB/9.0PEB
S1100VG-4T9.0GEB/11PEB 160 326 340 222 194 φ7
S1100VG-4T11GEB/15PEB
S1100VG-4T15GEB/18PEB
S1100VG-4T18GEB/22PEB 200 460 485 260 230 φ10
S1100VG-4T22GEB/30PEB
S1100VG-4T30GEB/37PE
S1100VG-4T37GE/45PE 220 545 565 330 252 φ10
S1100VG-4T45GE/55PE
S1100VG-4T55GE/75PE 300 563 588 380 266 φ12
S1100VG-4T75GE/93PE 320 635 660 460 290 φ12
S1100VG-4T93GE/110PE
S1100VG-4T110GE/132PE 340 845 875 475 305 φ12
S1100VG-4T132GE/160PE
S1100VG-4T160GE/185PE 380 1066 1100 520 355 φ12
S1100VG-4T185GE/200PE
S1100VG-4T160GE/185PE(cabinet) 370 855 890 520 355 φ12
S1100VG-4T185GE/200PE(cabinet)
S1100VG-4T200GE/220PE 500 1320 1360 700 380 φ14
S1100VG-4T220GE/250PE
S1100VG-4T250GE/280PE
S1100VG-4T280GE/315PE
S1100VG-4T315GE/355PE 750 1300 1350 900 455 φ16
S1100VG-4T355GE/400PE
S1100VG-4T400GE/450PE
 
If you have any question , pls let me know .

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier