Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 79/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Z900 frequency inverter | |
Standard functions |
Control mode | Sensorless flux vector control (SFVC) Voltage/Frequency (V/F) control |
Maximum frequency | Vector control: 0-300 Hz V/F control: 0-3200Hz |
|
Carrier frequency | 1 kHz-16 kHz The carrier frequency can be automatically adjusted based on the load features. |
|
Input frequency resolution |
Dgital setting: 0.01 Hz Analog setting: maximum frequency x 0.025% |
|
Startup torque | G type: 0.5 Hz/150% (SFVC); P type: 0.5 Hz/100% |
|
Speed range |
1:100 (SFVC) |
|
Speed stability accuracy | ± 0.5% (SFVC) |
|
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. P type: 60s for 120% of the rated current, 3s for 150% of the rated current. |
|
Torque boost | Auto-boost Customized boost 0.1%-30.0% |
|
V/F curve |
Liner V/F curve Multi-point V/F curve N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) |
|
V/F separation | Two types: complete separation; half separation | |
Ramp mode |
Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0-6500.0s |
|
DC braking | DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0-36.0s Braking action current value: 0.0%-100.0% |
|
JOG control |
JOG frequency range: 0.00-50.00 Hz JOG acceleration/deceleration time: 0.0-6500.0s |
Item | Z900 AC drive | |
Standard functions |
Multiple preset speeds | It implements up to 16 speeds via the simple PLC function or by input(X) terminal states |
Built-in PID | It realizes process-controlled closed loop control system easily. | |
Auto voltage regulation (AVR) |
It can keep constant output voltage automatically when the mains voltage changes. | |
Over-voltage/ Over-current stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over-voltage/over-current. |
|
Torque limit and torque control |
It can limit the torque automatically and prevent frequent over-current tripping during the running process. | |
Power dip ride through | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for short time. |
|
Rapid current limit | It helps to avoid frequent over-current faults of the AC drive. | |
High performance | high-performance current vector control technology. |
|
Timing control | Time range: 0.0-6500.0 minutes | |
Communication methods | RS485 | |
Protection mode | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. |
|
Input and output | Input terminal | 6 digital input terminals, one of which supports up to 100 kHz high-speed pulse input. 1 analog input terminals, switchable between 0-10 V input and 4-20 mA input. |
Frequency source | Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. | |
Auxiliary frequency source | There are ten auxiliary frequency sources.It can implement fine tuning of auxiliary frequency and frequency synthesis. |
|
Running command source | Operation panel/Control terminals/Serial communication port You can perform switchover between these sources in various ways. |
|
Output terminal | 1 digital output terminal 1 relay output terminal 1 analog output terminal :that supports 0-20 mA current output or 0-10 V voltage output |
Item | Z900 VFD | |
operation on the operation panel |
LED display | It displays the parameters. |
Key locking and function selection |
It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. |
|
Environment | Installation location | Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil fog, steam, drip or salt. |
Altitude | Lower than 1000 m | |
Ambient temperature | -10°C ~40°C (de-rated if the ambient temperature is between 40°C and 50°C) |
|
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9 m/s (0.6 g) | |
Storage temperature | -20°C~60°C |
Quanzhou Machtric Automation Equipment Co., Ltd is a company who manage international High Tech Products in the guidance of International Business .
With the help of the Strength R&D, System Engineering , taking advantage of the its abundant international trade resources, we have solved many problems for different customers.
At the same time, we have managed many another famous foreign brand in multi-level. We would like to be one of the most popular Industry Automation Solution Suppliers.
We try to provide wisdom, individual product solution.
Another Product
More than 15 years - we are more than 15 years professional manufacture frequency inverter
More than 50 countries- we exported our products to more than 50 countries all over the world.
Professional work team- we can accept OEM ODM
Powerful production capacity - we can offer a large quantity products each month.
Certification -we have passed CE
We offer 24 hours service
Welcome to you any time visit our factory