Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
S800E | ||
Power Supply |
Rated voltage, Frequency | One-phase/Three-phase AC 220V 50/60Hz |
Voltage Range | 220V: 170~240V | |
Output | Voltage Range | 220V: 0~220V |
Frequency Range | 0.10~400.00Hz | |
Control method | V/F control, Space vector control. | |
Indication | Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/ current, DC bus voltage, the temperature and so on. | |
Control SpeciAlations | Output Frequency Range |
0.10Hz~400.00Hz |
Frequency Setting Resolution |
Digital input: 0.01Hz, analog input: 0.1% of maximum output frequency |
|
Output Frequency Accuracy |
0.01Hz | |
V/F Control | Setting V/F curve to satisfy various load Requirements. |
|
Torque Control |
Auto increase: auto raise torque by loading Condition; Manual increase: enable to set 0.0~20.0% of raising torque. |
|
Multifunctional Input Terminal |
Four multi-function input terminals, realizing functions including fifteen section speed control, Program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions |
|
Multifunctional Output Terminal |
1 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other Information and warnings. |
|
Acceleration/ deceleration Time Setting | 0~999.9s acceleration/deceleration time can be set individually. | |
Other functions | PID Control | Built-in PID control |
RS485 | Standard RS485 communication function(MODBUS) | |
Frequency Setting | Analog input: 0 to 10 V, 0 to 20mA can be selected; Digital input:Input using the setting dial of the operation panel or RS485 or UP/DOWN. Note:AVI terminals can be used to select an analog voltage input(AV) and analog current input(AI) through the switch J2. Note: AVI terminals can be used to select an Analog voltage input (AV) and analog current Input(AI) through the switch J2. |
|
Multi-speed | Four multifunction input terminals, 15 section speed can be set |
|
Automatic voltage ID ControlliAlation regulation |
Automatic voltage regulation function can be Selected |
|
Counter | Built-in 2 group of counters | |
Protection/Warning Function | Overload | 150%, 60 second(Constant torque) |
Over Voltage | Over voltage protection can be set. | |
Under Voltage | Under voltage protection can be set | |
Other Protections | Overheat,output short circuit,over current, and Parameter lock and so on. |
|
Environment | Ambient Temperature | -10ºC to 40ºC(non-freezing) |
Ambient Humidity | Max. 95% (non-condensing) | |
Altitude | Lower than 1000m | |
Vibration | Max.0.5G | |
Structure | Cooling Mode | Forced air cooling |
Protective Structure |
IP 20 | |
Installation | Mode | Wall-mounted or standard 35MM rail mounting |
Applicable Inverter Type | Input voltage | Motor Output (KW) |
Main Circuit Cable Type (mm2) |
Breaker Selection (A) |
Input Side Magnetic Contractor (A) |
S800-2T0.4GE | 220V | 0.4 | 0.75 | 10 | 9 |
S800-2T0.75GE | 220V | 0.75 | 0.75 | 16 | 12 |
S800-2T1.5GE | 220V | 1.5 | 1.5 | 25 | 18 |