Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 100/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Product Specification:
Items |
S800E |
||
PowerSupply |
Rated voltage, Frequency |
One-phase/Three-phase AC 220V 50/60Hz |
|
Voltage Range |
220V: 170~240V;380V:330V-440V |
||
Output |
Voltage Range |
220V: 0~220V;380V:0-380V |
|
Frequency Range |
0.10~400.00Hz |
||
Control method |
V/F control, Space vector control. |
||
Indication |
Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/ current, DC bus voltage, the temperature and so on. |
||
Control SpeciAlations |
Output Frequency Range |
0.10Hz~400.00Hz |
|
Frequency Setting Resolution |
Digital input: 0.01Hz, analog input: 0.1% of maximum output frequency |
||
Output FrequencyAccuracy |
0.01Hz |
||
V/F Control |
Setting V/F curve to satisfy various load requirements. |
||
Torque Control |
Auto increase: auto raise torque by loadingCondition; Manual increase: enable to set0.0~20.0% of raising torque. |
||
MultifunctionalInput Terminal |
Four multi-function input terminals, realizing functions including fifteen section speed control, Program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions |
||
Multifunctional Output Terminal
|
1 multi-function output terminals for displaying of running, zerospeed, counter, external abnormity, program operation and other Information and warnings. |
||
Acceleration/ deceleration Time Setting |
0~999.9s acceleration/deceleration time can be set individually. |
||
Other functions |
PID Control |
Built-in PID control |
|
RS485 |
Standard RS485 communication function(MODBUS) |
||
Frequency Setting |
Analog input: 0 to 10 V, 4 to 20mA can be selected; |
||
Digital input:Input using the setting dial of theoperation panel or RS485 or UP/DOWN. |
|||
Note:AVI terminals can be used to select an analog voltage input(0-10v) and analog current input(4-20mA) through the switch J2. |
|||
Note: AVI terminals can be used to select an |
|||
Analog voltage input (AV) and analog current |
|||
Input(AI) through the switch J2. |
|||
Multi-speed |
Four multifunction input terminals, 15 section speed can be set |
||
Automatic voltage regulation |
Automatic voltage regulation function can be selected |
||
Counter |
Built-in 2 group of counters |
2.Product Advantage:
Model | Power Output |
Capacity |
Current Output |
Load Capacity |
Motor Equipped |
(KW) | (KWA) | (A) | (60s)(A) | (KW) | |
S800-2S0.4GE | 0.4 | 1 | 2.5 | 3.75 | 0.4 |
S800-2S.75GE | 0.75 | 2 | 5 | 7.5 | 0.75 |
S800-2S1.5GE | 1.5 | 2.8 | 7 | 10.5 | 1.5 |
S800-2S2.2GE | 2.2 | 4.2 | 11.0 | 16.5 | 2.2 |
Model | Power | Capacity | Current | Load | Motor |
Output | (KVA) | Output | Capacity | Equipped | |
(KW) | (A) | (60s)(A) | (KW) | ||
S800-4T0.75GE | 0.75 | 2.2 | 2.7 | 4.05 | 0.75 |
S800-4T1.5GE | 1.5 | 3.2 | 4.0 | 6.0 | 1.5 |
S800-4T2.2GE | 2.2 | 4.0 | 5.0 | 7.5 | 2.2 |