Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Z900E | |
tandard Function |
Control mode | Sensorless flux vector control(SFVC) Voltage/Frequency(V/F) control |
Maximum frequency | Vector control:0-320Hz V/F control:0-3200Hz |
|
Carrier frequency | 1-16kHz The carrier frequency is automatically adjusted based on the load features. |
|
Input frequency resolution | Digital setting:0.01Hz Analog setting:maximum frequency x 0.025% |
|
Startup torque | G type:0.5 Hz/150%(SFVC) P type:0.5 Hz/100% |
|
Speed range | 1:100(SFVC) | |
Speed stability accuracy | ±0.5%(SFVC) | |
Torque control accuracy | ± 5% (CLVC) | |
Overload capacity | G type:60s for 150% of the rated current,3s for 180% of the rated current. P type:60s for 120% of the rated current,3s for 150% of the rated current. |
|
Torque boost | Fixed boost Customized boost 0.1%-30.0% |
|
V/F Curve | Straight-line V/F curve Multi-point V/F curve N-power V/F curve(1.2-power,1.4-power,1.6-power,1.8-power,square |
|
V/F separation | Two types:complete separation;half separation | |
Ramp mode | Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0-6500.0s |
|
DC braking | DC braking frequency:0.00 Hz to maximum frequency Braking time:0.0-100.0s Braking action current value:0.0%-100% |
|
JOG control | JOG frequency range:0.00-50.00Hz JOG acceleration/deceleration time:0.0-6500.s |
|
Onboard multiple | It implements up to 16 speeds via the simple PLC function or combination of X terminal states | |
Onboard PID | It realizes process-controlled closed loop control systerm easily | |
Auto voltage regulation(AVR) | It can keep constant output voltage automatically when the main voltage changes | |
Overvoltage/Overcurrent stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current | |
Torque limit and control | It can limit the torque automatically and prevent frquent over current tripping during the running process | |
Instantaneous stop doesn't stop | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time | |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive | |
High performace | Control of asynchronous motor is implemented throgh the high-performance current vector Control technology |
|
Timing control | Time range:0.0-6500.0 minutes | |
Communication methods | RS485 | |
Running command channel | Given by the panel,control terminals.Serial communication port,can be switched by many ways | |
Frequency source | 10 kinds of frequency source,given by Digital analog voltage,analog current,Pulse,serial port.can be switched by man ways. | |
Auxiliary frequency source | 10 kinds of Frequency source,can easily realize Micro ajustment,frequency Synthesizer. | |
Input and output |
Input terminal | 6 digitak input terinals,one of which supports up to100kHz high-speed pulse input. 2 analog input terminal,one of which only supports 0-10v voltage input and the other supports 0-10v voltage input or 4-20 mA current input |
Output termianl | 1 digital output terminal 1 relay output terminal 1 analog output termianl:that supports 0-20 mA current output or 0-10V voltage ouput |
Extruder | Ball mill |
Elevator and lift | Textile equipment |
Paper Machinery | Screw output device |
Drawing Equipment | Dyeing plant |
Injiection plastic equipment | Air Conditioning systerm |
Machine tool equipment | Boiler system |
Chemical fiber equipment | water supply |
oil transportation installation | Food packaging machine |
Chemical machine | Spinning frame,ETC. |