Adjustable Speed Motor Drives /VSD/VFD/Vvsd

Product Details
Customization: Available
Application: High-performance Transducer
Output Type: Triple
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 5 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (10)
  • Adjustable Speed Motor Drives /VSD/VFD/Vvsd
  • Adjustable Speed Motor Drives /VSD/VFD/Vvsd
Find Similar Products

Basic Info.

Model NO.
S2800 series
Principle of Work
Vector Control Transducer
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Constant Torque Universal Type
Brand
Machtric
Price
Get Latest Price
Color
Whiter
Voltage
380V 415V
Power
7.5kw-110kw
Transport Package
Expoter Packing
Specification
as customer′s request
Trademark
Sanch
Origin
China
HS Code
85044090
Production Capacity
1000 PCS / Year

Product Description

Product Overview
Based on the modern motor control theory, S2800 series inverter uses constant torque drive, advanced field orientation vectorial control algorithm and sine-wave PWM control to gain direct control of the torque, provide low-speed high starting torque and precise control in the whole speed range, truly carries out the current vector control, and has reliable energy-saving features, which truly satisfies our user's needs as much as possible with high performance and provides reliable products for high-end industry

Applicable Industries:
Textile, dyeing and finishing, chemical fiber, paper making, wire drawing, cement manufacturing
Functions and Features:
Intelligent input terminal: Speed shift can be present in 8th phase, the first/second acceleration and deceleration time shift, prohibition of acceleration and deceleration; External interrupt input; Inching operation; Increasing/decreasing frequency setting terminal
Intelligent output terminal: During running, frequency arrival and output, non-zero speed, over-torque output, low-voltage detection of external interrupt indication, operating mode indication, abnormal malfunction output, and external abnormal interrupt
Built-in Function: Upper and lower limits setting of output frequency, instantaneous restart for power failure, restart for abnormal malfunction, automatic voltage output regulation, anomaly records parameter hold, parameters reset to the factory defaults, prohibition of reversion, over-current stall prevention, over-voltage stall prevention, electronic thermal relay
Protection Function: Protection of inverter unit phase, accelerated over-current, decelerated over current, constant-speed over-current, acceleration over-voltage, decelerated over-voltage, constant-speed over-voltage, bus under-voltage failure, motor overload, Inverter overload, open-phase at output side(75kw+models), rectification module overheating, overheating fault of inverter module, external fault, communication fault, current detection fault, motor self-learning fault, EEPROM operational fault, PID feedback disconnection fault, braking unit fault
Safety self-checking function: Electrifying of the inverter, complete safety self-checking of software and hardware by the system
Standby display function: There are totally 9 parameters of halt mode which can be chosen to display or not; There are totally 14 parameters of operation mode which can be chosen to display or not
V/F curve setup control /vector control function

Function of energy-saving running option: During no-load or light-load running of motor, adjust the output voltage properly by detecting load current to achieve automatic energy saving. (This function is especially effective on the load of blower or pump )
Function of automatic fault detection and recording: Detection function of the previous two faults' types; Recording function of the previous fault's type, voltage, current, running frequency, output/input terminal state.
Wobble frequency function: Applicable to industries such as textile and chemical fiber or occasions which need traverse or winding function
Controlling CharacteristicsControl modeV/F control Vector control without PG
Output range of frequency0.01~600.0Hz
Frequency setting analyzing degree0.01Hz
Output frequency analyzing degree0.01Hz
PWM load wave frequencyAvailable to modulate from 0.5 to 15 kHz
Torque increaseVector control without PG: 0.5Hz/150%(SVC)
Jog frequency3 points can be set from 0.01 to 600.0Hz
Acceleration/deceleration time0.01 to 3600.0 seconds. (Acceleration /deceleration time in 2 phases can be set separately)
Stall Prevention LevelAccording to the load characteristics of motor, it' s available to be set as 100% to 200% of the rated current of the drive
DC brakingbraking 0 to 150% of the rated current. Starting time 0.0 to-50.0 sec, Stopping time 0.0-50.0 sec
Braking torque20% (125% shall be available if connected with purchase braking resistor externally)          (1-25HP braking resistor is installed inside; 30HP can connect externally with brake unit module)
speed regulation ratioVector control without PG: 1: 100
Operation characteristicsFrequency setting signalDigital OperatorSet by UP and DOWN
External terminals0-10VDC, 4-20mADC, Series Communication Board (RS-485)
Operation SignalDigital OperatorAvailable to be operated by RUN, STOP and JOG keys.
External terminals2 wire styles (Fwd/Stop, Rev/Stop, Run/Stop and Fed/Rev) /3 wire operation, JOG running, Serial Communication Board(RS-485)
Intelligent Input TerminalSpeed shift can be preset in 8 th phase; the first/second acceleration and deceleration time shift: prohibition of acceleration and deceleration; external interrupt; inching operation; increasing/decreasing frequency setting terminal
Intelligent Output TerminalDuring running, frequency arrival and output, , non-zero count agreement output, over torque output, external interrupt reference. Low voltage detection, operation mode reference, fault output and external fault interruption.
Analog signal outputCorrespond to actual output frequency or output current.
Fault signal contactFor ac drive failure, the contact is " on" (a relay with " c" contactor a open-collector output
Built-in FunctionUpper and lower limits setting of output frequency, instantaneous restart for abnormal malfunction, automatic voltage output regulation, anomaly records, parameter hold, parameters reset to the factory defaults, prohibition of reversion, over-current stall prevention, over-voltage stall prevention, electronic  thermal relay
Protection FunctionProtection of inverter unit  phase, accelerated over-current, decelerated over-current, constant-speed over-voltage, bus under-voltage failure, motor overload, inverter overload, open - phase at output side (75KW+models ), rectification modules overheating, overheating fault of inverter module, external fault, communication fault, current detection fault, motor self-learning fault, EEPROM operational fault, PID feedback disconnection fault, braking unit fault
Digital operatorConsisting of 8 functional keys, 7 step LED in 5 digits; 5 status LED indicators. Available to set frequency, display actual output frequency, output current, self-determined unit parameter overview of users, modify settings and for parameter locking, fault displaying. Available to perform running, stop, reset, fwd/rev run and jog run.
EnvironmentOperational Environment temperature-10° C to +50° C (+40° C ~ +50° C available when the dust cover is removed)
Storing temperature-20° C to + 60° C
Installation heightLower than 1000m, without corrosive gas, fluid and dust.
VibrationBelow 20Hz 9.80665m/s² (1g), 20~50 Hz 5.88m/s² (0.6g)
Protection degreesIP20 (Determined by the installation environment of the end-users. )

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier