Item | Z900E | |
tandard Function |
Control mode | Sensorless flux vector control(SFVC) Voltage/Frequency(V/F) control |
Maximum frequency | Vector control:0-320Hz V/F control:0-3200Hz |
|
Carrier frequency | 1-16kHz The carrier frequency is automatically adjusted based on the load features. |
|
Input frequency resolution | Digital setting:0.01Hz Analog setting:maximum frequency x 0.025% |
|
Startup torque | G type:0.5 Hz/150%(SFVC) P type:0.5 Hz/100% |
|
Speed range | 1:100(SFVC) | |
Speed stability accuracy | ±0.5%(SFVC) | |
Torque control accuracy | ± 5% (CLVC) | |
Overload capacity | G type:60s for 150% of the rated current,3s for 180% of the rated current. P type:60s for 120% of the rated current,3s for 150% of the rated current. |
|
Torque boost | Fixed boost Customized boost 0.1%-30.0% |
|
V/F Curve | Straight-line V/F curve Multi-point V/F curve N-power V/F curve(1.2-power,1.4-power,1.6-power,1.8-power,square |
|
V/F separation | Two types:complete separation;half separation | |
Ramp mode | Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0-6500.0s |
|
DC braking | DC braking frequency:0.00 Hz to maximum frequency Braking time:0.0-100.0s Braking action current value:0.0%-100% |
|
JOG control | JOG frequency range:0.00-50.00Hz JOG acceleration/deceleration time:0.0-6500.s |
|
Onboard multiple | It implements up to 16 speeds via the simple PLC function or combination of X terminal states | |
Onboard PID | It realizes process-controlled closed loop control systerm easily | |
Auto voltage regulation(AVR) | It can keep constant output voltage automatically when the main voltage changes | |
Overvoltage/Overcurrent stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current | |
Torque limit and control | It can limit the torque automatically and prevent frquent over current tripping during the running process | |
Instantaneous stop doesn't stop | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time | |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive | |
High performace | Control of asynchronous motor is implemented throgh the high-performance current vector Control technology |
|
Timing control | Time range:0.0-6500.0 minutes | |
Communication methods | RS485 | |
Running command channel | Given by the panel,control terminals.Serial communication port,can be switched by many ways | |
Frequency source | 10 kinds of frequency source,given by Digital analog voltage,analog current,Pulse,serial port.can be switched by man ways. | |
Auxiliary frequency source | 10 kinds of Frequency source,can easily realize Micro ajustment,frequency Synthesizer. | |
Input and output |
Input terminal | 6 digitak input terinals,one of which supports up to100kHz high-speed pulse input. 2 analog input terminal,one of which only supports 0-10v voltage input and the other supports 0-10v voltage input or 4-20 mA current input |
Output termianl | 1 digital output terminal 1 relay output terminal 1 analog output termianl:that supports 0-20 mA current output or 0-10V voltage ouput |
|
Operation on the operation panel |
LED display | It displays the parameters |
Key locking and cuntion selection | It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function | |
Protection mode | Motor short-circuit detection at power-on,output phase loss protection,over-curent protection,over-voltage protection,under voltage protection,overheat protection and overload protection. | |
Environment |
Installation location | Indoor,avoid direct sunlight,dust,corrosive gas,combustible gas,oil smoke,vapour drip or salt |
Altitude | Lower than 1000m(Lower the grades when using higher then 1000m) | |
Ambient temperature | -10°C~40°C(Lower the grades if the ambient temperature is between 40°C and 50°C) | |
Humidity | Less than 95%RH,without condensing | |
Vibration | Less than 5.9 m/s² (0.6g) | |
Storage temperature | -20°C~60°C |
Model | Rated output power | Rated Output Current |
Overload Capacity |
Applicable motor |
(KW) | (A) | (60s)(A) | (KW) | |
Z900-2S0.4GE | 0.4 | 5.4 | 3.75 | 0.4 |
Z900-2S0.75GE | 0.75 | 7.2 | 7.5 | 0.75 |
Z900-2S1.5GE | 1.5 | 10 | 10.5 | 1.5 |
Z900-2S3.7GE | 3.7 | 16 | 10.0 | 3.7 |
Z900-2S5.5GE | 5.5 | 21 | 20 | 5.5 |
Z900-2S7.5GE | 7.5 | 31 | 30 | 7.5 |
Model | Rated output power | Rated Output Current |
Overload Capacity |
Applicable motor |
(KW) | (A) | (60s)(A) | (KW) | |
Z900-4T0.4GE | 0.4 | 3.4 | 1.2 | 0.4 |
Z900-4T0.75GE | 0.75 | 3.8 | 2.5 | 0.75 |
Z900-4T1.5GE | 1.5 | 5 | 3.7 | 1.5 |
Z900-4T2.2GE | 2.2 | 5.8 | 5.0 | 2.2 |
Z900-4T3.7GE/5.5PE | 3.7/5.5 | 10.0/15.0 | 9.0/13.0 | 3.7/5.5 |
Z900-4T5.5GE | 5.5 | 15 | 13 | 5.5 |
Z900-4T7.5GE/11PE | 7.5 | 20 | 17 | 7.5 |
Z900-4T11GE/15PE | 11/15 | 26/35 | 25/32 | 11/15 |
Z900-4T15GE/18.5PE | 15/18.5 | 35/38 | 32/37 | 15/18.5 |
Z900-4T18.5GE/22PE | 18.5/22 | 38/46 | 37/45 | 18..5/22 |
Z900-4T22GE/30PE | 22/30 | 46/62 | 45/60 | 22/30 |
Z900-4T30GE/37PE | 30/37 | 62/76 | 60/75 | 30/37 |
Z900-4T37GE/45PE | 37/45 | 76/90 | 75/90 | 37/45 |
Z900-4T45GE/55PE | 45/55 | 90/105 | 90/110 | 45/55 |
Z9010-4T55GE | 55 | 105 | 110 | 55 |
Z900-4T75PE | 75 | 140 | 150 | 75 |
Z900-4T75GE/90E | 75/90 | 140/160 | 150/176 | 75/90 |
Z900-4T90GE/110PE | 90/110 | 160/210 | 176/210 | 90/110 |
Z900-4T110GE/132PE | 110/132 | 210/240 | 210/253 | 110/132 |
Z900-4T132GE/160PE | 132/160 | 240/290 | 253/300 | 132/160 |
Z900-4T160GE/185PE | 160/185 | 290/330 | 300/340 | 160/185 |