Application: | Three Phase Transducer, General Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Input Voltage | 220V | 440V | |||||||||||||
Model number: S1100-2T/4T***G | 0.75 | 1.5 | 2.2 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | ||
Output | Applicable motor power (KW) | 0.75 | 1.5 | 2.2 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | |
Output rated current (A) | 5 | 6.5 | 11 | 3.0 | 4.2 | 5.5 | 8.2 | 13 | 18 | 24 | 32 | 38 | 45 | ||
Max output voltage (A) | Input power | ||||||||||||||
Over load capacity | 150% of rated output current and run for 65 seconds | ||||||||||||||
Power | Phase. Voltage. Frequency | 1-phase/3-phase 200-240V 50/60HZ | 3-phase 380-460V 50/60HZ | ||||||||||||
Allowable variation range of Voltage Frequency | Voltage: ± 15% Frequency: ± 5% | ||||||||||||||
Input current (A) | 11/7.4 | 15/10 | 27/15 | 4.2 | 6.0 | 7.2 | 8.5 | 14 | 20.6 | 28 | 30 | 39 | 49 | ||
Controlling Characteristics | Control mode | Adopting SVPWM modulating techniques (V/F control and Speed Sensor-less Vector) | |||||||||||||
Output range of frequency | 0.01~400.0Hz | ||||||||||||||
Frequency setting analyzing degree | 0.01Hz | ||||||||||||||
Output frequency analyzing degree | 0.01Hz | ||||||||||||||
PWM load wave frequency | Available to modulate from 2 to 10kHz | ||||||||||||||
Torque increase | Auto torque-increase and auto slip compensation at 2 Hz the starting torque can reach 150% of rated torque. | ||||||||||||||
Jog frequency | 3 points can be set from 0.01 to 400.0Hz | ||||||||||||||
Acceleration/deceleration time | 0.01 to 600.0 seconds. (2 steps of accel/decel time can be set separately. ) | ||||||||||||||
Stall Prevention Level | According to the load characteristics of motor, it' s available to be set as 50 to 200% of the rated current of the drive | ||||||||||||||
DC braking | Available to be operated from 0.01 to 400.0 Hz from STOP, braking 0 to 100% of the rated current. Starting time 0.0 to-60.0 sec, Stopping time 0.0-60.0 sec | ||||||||||||||
Braking torque | 20% (125% shall be available if connected with purchase braking resistor externally) (or 1 to 25HP, equipped within the electric crystals, for 30 HP, braking unit module shall be connected externally. ) | ||||||||||||||
V/F curve | V/F curve available to be set | ||||||||||||||
Operation characteristics | Frequency setting signal | Digital Operator | Set by UP and DOWN | ||||||||||||
External terminals | 0-10VDC, 4-20mADC, Series Communication Board (RS-485) | ||||||||||||||
Running operatisignal | Digital Operator | Available to be operated by RUN, STOP and JOG keys. | |||||||||||||
External terminals | 2 wire styles (Fwd/Stop, Rev/Stop, Run/Stop and Fed/Rev) /3 wire operation, JOG running, Serial Communication Board(RS-485) | ||||||||||||||
Intelligent Input Terminal | Switching of 16 step pre-set available speed; Switching of First/Second acceleration/deceleration time; prohibiting acceleration/deceleration and external interrupt input; Jog running UP/DOWN frequency terminal setting; Count terminals | ||||||||||||||
Intelligent Output Terminal | During running, frequency agreement output, non-zero count agreement output, over torque output, external interrupt reference. Low voltage detection, operation mode reference, fault output and external fault interruption. | ||||||||||||||
Analog signal output | Correspond to actual output frequency or output current. | ||||||||||||||
Fault signal contact | Contact of ON at AC motor drive (Relay with one C contact or two open collector output. ) | ||||||||||||||
Built-in Function | Setting max/min output frequency; momentary power off restarting; fault restaring; setting of S curve acceleration/deceleration time; auto-voltage stabilizing output modulation; digital frequency output signal; fault records; parameters locking; reset to factory setting; inhibiting reverse run; over current stalling prevention, over voltage stalling prevention, electrical thermal relay. | ||||||||||||||
Protection Function | Over current; over voltage, low voltage; external fault interruption input; motor over load; GFF: grounding protection(For optional use); over load of the drive and drive overheating | ||||||||||||||
Digital operator | Consisting of 8 functional keys, 7 step LED in 5 digits; 5 status LED indicators. Available to set frequency, display actual output frequency, output current, self-determined unit parameter overview of users, modify settings and for parameter locking, fault displaying. Available to perform running, stop, reset, fwd/rev run and jog run. | ||||||||||||||
Environment | Operational Environment temperature | -10° C to +50° C (+40° C ~ +50° C available when the dust cover is removed) | |||||||||||||
Storing temperature | -20° C to + 60° C | ||||||||||||||
Installation height | Lower than 1000m, without corrosive gas, fluid and dust. | ||||||||||||||
Vibration | Below 20Hz 9.80665m/s² (1g), 20~50 Hz 5.88m/s² (0.6g) | ||||||||||||||
Protection degrees | Determined by the installation environment of the end-users. |