Heavy Load Soft Starter 380V 3phase Motor Starter

Product Details
Customization: Available
Application: Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Still deciding? Get samples of US$ 569/Piece
Request Sample
Gold Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (10)
  • Heavy Load Soft Starter 380V 3phase Motor Starter
  • Heavy Load Soft Starter 380V 3phase Motor Starter
  • Heavy Load Soft Starter 380V 3phase Motor Starter
  • Heavy Load Soft Starter 380V 3phase Motor Starter
Find Similar Products

Basic Info.

Model NO.
CMC-LX
Switch Mode
High Carrier Frequency PWM Control
Main Circuit Type
Current
Voltage of Power Supply
High Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Simple Type, Elevator Special
Brand
Machtric
Product Name
Heavy Load Soft Starter Motor Starter Soft Motor S
Control Voltage
24 VDC Control Voltage
Phase
3- Phase (Two-Phases Controlled)
Bypass
Internal Bypass Contacts for Run
Panel
Error and Run LEDs
Mounting
DIN Rail Mounting
Widths
Two Standard-Size Widths: 45mm & 55mm
Accessories
Fan
Transport Package
Box
Specification
compact
Trademark
machtric
Origin
China
Production Capacity
20000PCS/Month

Product Description

Heavy load soft starter motor starter soft motor starter 

Themotor soft starters use thyristors for controlled reduced voltage motor starting and stopping. These low voltage soft starters then switch to internal contacts for efficient running at the rated speed.

  • 5-40A  208-460V
  • 24 VDC control voltage
  • 3- Phase (two-phases controlled)
  • Internal bypass contacts for run
  • Error and Run LEDs
  • DIN rail mounting
  • Two standard-size widths: 45mm & 55mm
  • Six error/trip indications: AC Supply, Control Supply, Overheated, Bypass Failure, Shear Pin, Overcurrent
  • UL listed* (E333109) *(optional fans are UL recognized: E132139, E77551, E89936, CE, RoHS)
  • Accessories: Cooling fan (increases # of motor soft starts/hour
Control power AC110V--220V±15%, 50/60Hz
Three-phase power Standard wiring AC380V, 660V, 1140V±15%  
Internal delta wiring AC380V±15%
Nominal current 18A--1000A, 22 rated values in total
Applicable motor Ordinary squirrel cage AC asynchronous motor
Start ramp mode Voltage ramp start and current ramp start
Stop mode Free stop and soft stop
Logical input Impedance 1.8 KΩ, power supply +24V
Start frequency Frequent or infrequent start available, start is advised not to exceed 10 times each other
Protective function Phase failure, overcurrent, short circuit, SCR protection, overheat, phase current unbalance, wiring and inner fault
IP IP00, IP20
Cooling type Natural cooling or forced air cooling
Installation type Wall mounted
Environmental condition When sea altitude is above 2,000m, soft starter should be derated for use.
Ambient temperature: -25-+45°C
Relative humidity: less than 95%(20°C±5°C)
Free of flammable, explosive and corrosive gas or conductive dust. Good ventilation for indoor installation and vibration is less than 0.5G

Heavy Load Soft Starter 380V 3phase Motor Starter



Technical characteristics
1. Unique SCR trigger closed-loop control algorithm
Unique SCR closed-loop control, specially designed for standard and heavy loads. The user can select the current limit start and the voltage ramp start according to the load condition to achieve an absolutely smooth torque-free oscillation start effect.
2.Control accuracy, real-time efficiency
High-performance CORETX-M3 32-bit core CPU for center control, fast speed, high precision, strong anti-interference ability
3.Beautiful appearance
Patented main circuit three-in and six-out structure, built-in current transformer scheme, convenient wiring and high reliability
4.Optional standard MODBUS-RTU protocol

5.Integrated advanced protection
It has protection functions such as input and output phase loss, overload, overcurrent, phase current imbalance, thyristor over temperature, etc., to protect the motor and related equipment in all directions.
6.Full refractory
90kw or less is a fully molded shell structure, processed with flame-retardant ABS material. The upper cover of 90KW and above is made of plastic shell structure, and the main frame is made of aluminum-zinc plate material. It has heat resistance and corrosion resistance.
7.External lead panel
The panel can be externally led to the operating surface of the device for remote operation through the fuselage interface, which is convenient for on-site use.
8.Simple maintenance
A monitoring signal coding system consisting of a 4-digit digital display that monitors the operating conditions of system equipment 24 hours a day, while providing fast fault diagnosis


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.