Customization: | Available |
---|---|
Application: | Three Phase Transducer, Single-phase Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product specification:
Item |
S3800E | S3800E | |
Based functions | Control mode | V/F(Voltage/Frequency) control | |
Sensorless flux vector control (VC) | |||
Closed-loop vector control (CVC) | |||
Maximum frequency | Vector control: 0-320 Hz | ||
V/F control: 0-3200Hz | |||
Carrier frequency | 1.0-16.0 kHz | ||
The carrier frequency is automatically adjusted based on the load features. | |||
Input frequency esolution | Dgital setting: 0.01 Hz | ||
Analog setting: 0.025% of maximum frequency | |||
Startup torque | G type: 0.5 Hz/150% (VC); 0 Hz/180% (CVC) | ||
P type: 0.5 Hz/100% | |||
Speed range | 1:100 (VC) | ||
1:1000 (CVC) | |||
Speed stability accuracy | ± 0.2% (VC) | ||
± 0.02% (CVC) | |||
Torque control accuracy | ± 5% (CVC) | ||
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. | ||
P type: 60s for 120% of the rated current, 3s for 150% of the rated current. | |||
Torque boost | Auto boost | ||
Customized boost 0.1%-30.0% | |||
V/F curve | Line V/F curve | ||
Multi-point V/F curve | |||
N-power V/F curve (1.2-power, 1.4-power, 1.6-power,1.8-power, square) | |||
V/F separation | two types: complete separation; half separation | ||
Ramp mode | Straight-line ramp | ||
S-curve ramp | |||
Four groups of acceleration/deceleration time with the range of 0.0-6500.0s | |||
DC braking | DC braking frequency: 0.00 Hz to maximum frequency | ||
Braking time: 0.0-100.0s | |||
Braking action current value: 0.0%-100.0% | |||
JOG control | JOG frequency range: 0.00-50.00 Hz | ||
JOG acceleration/deceleration time: 0.0-6500.0s | |||
Onboard multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of terminal states | ||
Onboard PID | It realizes process-controlled closed loop control system easily. | ||
Auto voltage | It can keep constant output voltage automatically when the mains voltage changes. | ||
regulation (AVR) | |||
Overvoltage/ Overcurrent stall control | The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to overvoltage/over current. | ||
Torque limit and control | It can limit the torque automatically and prevent frequent over current tripping during the running process.Torque control can be implemented in the CVC mode. | ||
Individualized functions | Support for multiple PG card | Support for rotating transformer PG card,differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card | |
Power dip ride through | The load feedback energy compensates the voltage | ||
reduction so that the AC drive can continue to run for a | |||
short time. | |||
Rapid current limit | It helps to avoid frequent over current faults of the AC drive. | ||
High performance | Control of asynchronous motor and synchronous motor are | ||
implemented through the high-performance current vector | |||
control technology. | |||
Timing control | Time range: 0.0-6500.0 minutes | ||
Communication methods | MODBUS-RTU,PROFIBUS-DP,CAN | ||
Protection mode | Motor short-circuit detection at power-on, input/output | ||
phase loss protection, over current protection, overvoltage | |||
protection, under voltage protection, overheat protection and overload protection. | |||
Input and output | Input terminal | 8 digital input terminals, one of which supports up to | |
100 kHz high-speed pulse input. | |||
2 analog input terminals, one of which only supports | |||
0-10 V voltage input and the other supports 0-10 V voltage input or 4-20 mA current input. | |||
Frequency source | Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. | ||
Auxiliary frequency source | There are ten auxiliary frequency sources.It can implement | ||
fine tuning of auxiliary frequency and frequency synthesis. | |||
Running command source | Operation panel/Control terminals/Serial communication port | ||
You can perform switchover between these sources in | |||
various ways. | |||
Output terminal | 1 high-speed pulse output terminal (open-collector) that | ||
supports 0-100 kHz square wave signal output | |||
1 digital output terminal | |||
2 relay output terminal | |||
2 analog output terminal :that supports 0-20 mA current output or 0-10 V voltage output | |||
operation on the operation panel | LED display | It displays the parameters. | |
Key locking and | It can lock the keys partially or completely and define the | ||
function selection | function range of some keys so as to prevent mis-function. | ||
Optional parts | Rotating transformer PG card,differential input PG card, UVW differential input PG card, resolver PG card and OC input PG card | ||
Environment | Installation location | Indoor, free from direct sunlight, dust, corrosive gas, | |
combustible gas, oil smoke, vapour, drip or salt. | |||
Altitude | Lower than 1000 m | ||
Ambient temperature | -10°C ~40°C (de-rated if the ambient temperature is | ||
between 40°C and 50°C) | |||
Humidity | Less than 95%RH, without condensing | ||
Vibration | Less than 5.9 m/s2 (0.6 g) | ||
Storage temperature | -20°C~60°C |
Product show:
Target Market of S3800E series Inverter
Extruder | Mill Ball |
Elevator and lift | Textile equipment |
Paper Machinery | Screw output device |
Drawing Equipment | Dyeing plant |
Injiection plastic equipment | Air Conditioning systerm |
Machine tool equipment | Boiler system |
Chemical fiber equipment | water supply,oil transportation installation.Etc |