Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 126/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Z900 frequency inverter | |
Standard functions |
Control mode | Sensorless flux vector control (SFVC) Voltage/Frequency (V/F) control |
Maximum frequency | Vector control: 0-300 Hz V/F control: 0-3200Hz |
|
Carrier frequency | 1 kHz-16 kHz The carrier frequency can be automatically adjusted based on the load features. |
|
Input frequency resolution |
Dgital setting: 0.01 Hz Analog setting: maximum frequency x 0.025% |
|
Startup torque | G type: 0.5 Hz/150% (SFVC); P type: 0.5 Hz/100% |
|
Speed range |
1:100 (SFVC) |
|
Speed stability accuracy | ± 0.5% (SFVC) |
|
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. P type: 60s for 120% of the rated current, 3s for 150% of the rated current. |
|
Torque boost | Auto-boost Customized boost 0.1%-30.0% |
|
V/F curve |
Liner V/F curve Multi-point V/F curve N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) |
|
V/F separation | Two types: complete separation; half separation | |
Ramp mode |
Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0-6500.0s |
|
DC braking | DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0-36.0s Braking action current value: 0.0%-100.0% |
|
JOG control |
JOG frequency range: 0.00-50.00 Hz JOG acceleration/deceleration time: 0.0-6500.0s |
Item | Z900 | |
Standard functions |
Multiple preset speeds | It implements up to 16 speeds via the simple PLC function or by input(X) terminal states |
Built-in PID | It realizes process-controlled closed loop control system easily. | |
Auto voltage regulation (AVR) |
It can keep constant output voltage automatically when the mains voltage changes. | |
Over-voltage/ Over-current stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over-voltage/over-current. |
|
Torque limit and torque control |
It can limit the torque automatically and prevent frequent over-current tripping during the running process. | |
Power dip ride through | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. |
|
Rapid current limit | It helps to avoid frequent over-current faults of the AC drive. | |
High performance | high-performance current vector control technology. |
|
Timing control | Time range: 0.0-6500.0 minutes | |
Communication methods | RS485 | |
Protection mode | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. |
|
Input and output | Input terminal | 6 digital input terminals, one of which supports up to 100 kHz high-speed pulse input. 1 analog input terminals, switchable between 0-10 V input and 4-20 mA input. |
Frequency source | Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. | |
Auxiliary frequency source | There are ten auxiliary frequency sources.It can implement fine tuning of auxiliary frequency and frequency synthesis. |
|
Running command source | Operation panel/Control terminals/Serial communication port You can perform switchover between these sources in various ways. |
|
Output terminal | 1 digital output terminal 1 relay output terminal 1 analog output terminal :that supports 0-20 mA current output or 0-10 V voltage output |
Item | Z900 | |
operation on the operation panel |
LED display | It displays the parameters. |
Key locking and function selection |
It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. |
|
Environment | Installation location | Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil fog, steam, drip or salt. |
Altitude | Lower than 1000 m | |
Ambient temperature | -10°C ~40°C (de-rated if the ambient temperature is between 40°C and 50°C) |
|
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9 m/s2 (0.6 g) | |
Storage temperature | -20°C~60°C |
Model No. | Input Voltage | Rated Output Power (KW) | Rated Input Current(A) | Rated Output Current (A) | Motor Power (KW) |
Z900-2S0.4GE | 1PH AC 220V•50/60Hz |
0.4 | 5.4 | 2.4 | 0.4 |
Z900-2S0.75GE | 1PH AC 220V•50/60Hz |
0.75 | 7.2 | 4.5 | 0.75 |
Z900-2S1.5GE | 1PH AC 220V•50/60Hz |
1.5 | 10 | 7.0 | 1.5 |
Z900-2S2.2GE | 1PH AC 220V•50/60Hz |
2.2 | 16 | 10.0 | 2.2 |
Z900-2S3.7GE | 1PH AC 220V•50/60Hz |
3.7 | 23 | 16.0 | 3.7 |
Z900-4T0.75GE | 3PH AC 380V·50/60Hz |
0.75 | 3.8 | 2.5 | 0.75 |
Z900-4T1.5GE | 3PH AC 380V·50/60Hz |
1.5 | 5 | 3.7 | 1.5 |
Z900-4T2.2GE | 3PH AC 380V·50/60Hz |
2.2 | 5.8 | 5.0 | 2.2 |
Z900-4T3.7GE/5.5GP | 3PH AC 380V·50/60Hz |
3.7/5.5 | 10.0/15.0 | 9.0/13.0 | 3.7/5.5 |
Z900-4T5.5GE | 3PH AC 380V·50/60Hz |
5.5 | 15.0 | 13.0 | 5.5 |
Z900-4T7.5GE | 3PH AC 380V·50/60Hz |
7.5 | 14 | 17.5 | 7.5 |
Z900-4T7.5GE/11GP | 3PH AC 380V·50/60Hz |
7.5/11 | 20.0/26.0 | 17.0/25.0 | 7.5/11 |
Z900-11GE/15GP | 3PH AC 380V·50/60Hz |
11/15 | 26.0/35.0 | 25.0/32.0 | 11/15 |
Z900-15GE/ 18.5GP |
3PH AC 380V·50/60Hz |
15/18.5 | 35.0/38.0 | 32.0/37.0 | 15/18.5 |
Z900-18.5GE/ 22GP |
3PH AC 380V·50/60Hz |
18.5/22 | 38.0/46.0 | 37.0/45.0 | 18.5/22 |
Z900-22GE/30GP | 3PH AC 380V·50/60Hz |
22/30 | 46.0/62.0 | 45.0/60.0 | 22/30 |
Why choose us |
More than 15 years - we are more than 15 years professional manufacture frequency inverter More than 50 countries- we exported our products to more than 50 countries all over the world. Professional work team- we can accept OEM ODM Powerful production capacity - we can offer a large quantity products each month. Certification -we have passed CE We offer 24 hours service |