1. Open loop vector control.
2. It's general use.
3. Frequency range:0~400Hz.
4. Power range:1phase 220V (0.4~3.7kw) 3 phase 380V(0.75~315kw)
5. Protective structure: IP 20.
Item | ||
Standard functions |
Control mode | Sensorless flux vector control (SFVC) Voltage/Frequency (V/F) control |
Maximum frequency | Vector control: 0-300 Hz V/F control: 0-3200Hz |
|
Carrier frequency | 1 kHz-16 kHz The carrier frequency can be automatically adjusted based on the load features. |
|
Input frequency resolution |
Dgital setting: 0.01 Hz Analog setting: maximum frequency x 0.025% |
|
Startup torque | G type: 0.5 Hz/150% (SFVC); P type: 0.5 Hz/100% |
|
Speed range |
1:100 (SFVC) |
|
Speed stability accuracy | ± 0.5% (SFVC) |
|
Overload capacity | G type: 60s for 150% of the rated current, 3s for 180% of the rated current. P type: 60s for 120% of the rated current, 3s for 150% of the rated current. |
|
Torque boost | Auto-boost Customized boost 0.1%-30.0% |
|
V/F curve |
Liner V/F curve Multi-point V/F curve N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square) |
|
V/F separation | Two types: complete separation; half separation | |
Ramp mode |
Straight-line ramp S-curve ramp Four groups of acceleration/deceleration time with the range of 0.0-6500.0s |
|
DC braking | DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0-36.0s Braking action current value: 0.0%-100.0% |
|
JOG control |
JOG frequency range: 0.00-50.00 Hz JOG acceleration/deceleration time: 0.0-6500.0s |
Item | Z900 | |
Standard functions |
Multiple preset speeds | It implements up to 16 speeds via the simple PLC function or by input(X) terminal states |
Built-in PID | It realizes process-controlled closed loop control system easily. | |
Auto voltage regulation (AVR) |
It can keep constant output voltage automatically when the mains voltage changes. | |
Over-voltage/ Over-current stall control |
The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over-voltage/over-current. |
|
Torque limit and torque control |
It can limit the torque automatically and prevent frequent over-current tripping during the running process. | |
Power dip ride through | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. |
|
Rapid current limit | It helps to avoid frequent over-current faults of the AC drive. | |
High performance | high-performance current vector control technology. |
|
Timing control | Time range: 0.0-6500.0 minutes | |
Communication methods | RS485 | |
Protection mode | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. |
|
Input and output | Input terminal | 6 digital input terminals, one of which supports up to 100 kHz high-speed pulse input. 1 analog input terminals, switchable between 0-10 V input and 4-20 mA input. |
Frequency source | Digital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting. | |
Auxiliary frequency source | There are ten auxiliary frequency sources.It can implement fine tuning of auxiliary frequency and frequency synthesis. |
|
Running command source | Operation panel/Control terminals/Serial communication port You can perform switchover between these sources in various ways. |
|
Output terminal | 1 digital output terminal 1 relay output terminal 1 analog output terminal :that supports 0-20 mA current output or 0-10 V voltage output |
Item | Z900 | |
operation on the operation panel |
LED display | It displays the parameters. |
Key locking and function selection |
It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function. |
|
Environment | Installation location | Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil fog, steam, drip or salt. |
Altitude | Lower than 1000 m | |
Ambient temperature | -10°C ~40°C (de-rated if the ambient temperature is between 40°C and 50°C) |
|
Humidity | Less than 95%RH, without condensing | |
Vibration | Less than 5.9 m/s2 (0.6 g) | |
Storage temperature | -20°C~60°C |