Mini Frequency Inverter for Fan and Pump

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Triple
Gold Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (10)
  • Mini Frequency Inverter for Fan and Pump
  • Mini Frequency Inverter for Fan and Pump
  • Mini Frequency Inverter for Fan and Pump
  • Mini Frequency Inverter for Fan and Pump
  • Mini Frequency Inverter for Fan and Pump
  • Mini Frequency Inverter for Fan and Pump
Find Similar Products

Basic Info.

Model NO.
S800E
Switch Mode
Vf Control
Main Circuit Type
Current
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Current Variable-Frequency Drive
Function
Simple Type
Brand
Machtric
Type
AC-DC-AC
Output Type I
Tripe
Phase
3 Phase
Output Frequency
0~400Hz
Supply Power
AC
Vvvf
Variable Frequency Inverter
Transport Package
Standard Export Package
Specification
CE, ISO9001
Trademark
Machtric
Origin
China
HS Code
8504409999
Production Capacity
10000/Months

Product Description

Mini Frequency Inverter for Fan and Pump

S800 E Series
 
 User's Manual 
 
Micro Universal -Purpose Drives
 
Items S800E
Power
Supply
Rated voltage, Frequency  
One-phase/Three-phase AC 220V 50/60Hz
  Voltage Range  
220V: 170~240V
Output Voltage Range 220V: 0~220V
  Frequency Range 0.10~400.00Hz
Control method V/F control, Space vector control.
Indication Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/ current, DC bus voltage, the temperature and so on.
            Control   SpeciAlations Output Frequency
Range
0.10Hz~400.00Hz
  Frequency Setting
Resolution
Digital input: 0.01Hz, analog input: 0.1% of 
maximum output frequency
  Output Frequency
Accuracy
0.01Hz
  V/F Control Setting V/F curve to satisfy various load
Requirements.
  Torque
Control
Auto increase: auto raise torque by loading
Condition; Manual increase: enable to set
0.0~20.0% of raising torque.
  Multifunctional
Input Terminal
Four multi-function input terminals, realizing
functions including fifteen section speed control, Program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions
  Multifunctional
Output Terminal
1 multi-function output terminals for displaying
of running, zero speed, counter, external
abnormity, program operation and other
Information and warnings.
  Acceleration/ deceleration Time Setting 0~999.9s acceleration/deceleration time can be set individually.
                 Other      functions
 
PID Control Built-in PID control
  RS485 Standard RS485 communication function(MODBUS)
  Frequency Setting Analog input: 0 to 10 V, 0 to 20mA can be
selected;
Digital input:Input using the setting dial of the
operation panel or RS485 or UP/DOWN.
Note:AVI terminals can be used to select an
analog voltage input(AV) and analog current
input(AI) through the switch J2.
Note: AVI terminals can be used to select an
Analog voltage input (AV) and analog current
Input(AI) through the switch J2.
  Multi-speed Four multifunction input terminals, 15 section 
speed can be set
  Automatic
voltage 
Model Input Power
Output
(KW)
Capacity
(KVA)
Current
Output
(A)
Load
Capacity
(60s)(A)
Motor
Equipped
(KW)
S800-2T0.4GE 1PH/3PH
220V-
50/60HZ
0.4 1.0 2.5 3.75 0.4
S800-2T0.75GE 0.75 2.0 5.0 7.50 0.75
S800-2T1.5GE 1.5 2.8 7.0 10.50 1.5

Mini Frequency Inverter for Fan and Pump

About the inverter's installation environment, please ensure it is in accordance with the following condition:
1) Environment temperature from -10ºC to +40ºC
 
2) Environment humidity 0~95% without condensing
 
3) Away from direct sunlight
 
4) The environment does not contain corrosive gas and liquid
 
5) The environment does not contain dust, floating fiber and metal dust.
 
6) Far away from radioactive materials and combustible substances
 
7) Far away from electromagnetic interference sources ( as welder, high-powered machines)
 
8) The installation surface shall be firm. Without vibration, the vibration cannot be avoided, please add anti-vibration spacer to reduce vibration.
 
9) Please install the inverter to a location where it is good for ventilation, inspection and maintenance, and away from heating unit ( as brake resistor)
 
10) Preserved enough space for inverter installation, especially for multiple inverters installation, please pay attention to the laying position of the inverter, and install an extra cooling fan to keep the environment temperature lower than 45ºC.
Mini Frequency Inverter for Fan and Pump 
Mini Frequency Inverter for Fan and Pump
Mini Frequency Inverter for Fan and Pump
Mini Frequency Inverter for Fan and Pump


If you want to know other detail, please contact with us.



Variable Frequency Drive, Variable Speed Drive, Frequency Inverter, AC Driver, AC Drive, AC Motor Drive, VFD,VSD. Frequency Inverter,  VFD, VSD. Variable Speed Drive, Variable Voltage Variable Frequency Drive, Adjustable speed drive, Frequency converter,
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier