Customization: | Available |
---|---|
Application: | High Frequency Converter Transducer |
Output Type: | Single Phase or Three Phases |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items | S900E | ||
Power Supply |
Rated voltage, Frequency | Single phase/Three phase 220V 50/60Hz | |
Voltage Range | 220V: 170V~240V | ||
Output | Voltage Range | 220V: 0~220V | |
Frequency Range | 0.10`400.00Hz | ||
Control method | V/F control, Space vector control. | ||
Indication | Operating status/Alarm definition/interactive guidance: eg, frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. | ||
Control Specifications | Output Frequency Range | 0.10Hz~400.00Hz | |
Frequency Setting Resolution | Digital input: 0.01Hz, analog input: 0.1% of maximum output frequency | ||
Output Frequency Accuracy | 0.01Hz | ||
V/F Control | Setting V/F curve to satisfy various load requirements | ||
Torque Control | Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque | ||
Multifunctional lnput Terminal |
Six multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions | ||
Multifunctional Output Terminal |
2 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings | ||
Acceleration/deceleration Time Setting | 0~-999.9s acceleration/deceleration time can be set individually | ||
Other Functions | PID Control | Built-in PID control | |
RS485 | Standard RS485 communication function(MODBUS) | ||
Frequency Setting | Analog input: 0 to 10V, , 0 to 20mA can be selected; Dig ital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN |
||
Multi-speed | Six multifunction input terminals, 15section speed can be set | ||
Automatic voltage regulation | Automatic voltage regulation function can be selected | ||
Counter | Built - in 2group of counters | ||
Protection/ Warning Function |
Overload | 150%, 60 second(Constant torque) | |
Over Voltage | Over voltage protection can be set | ||
Under Voltage | Under voltage protection can be set | ||
Other Protections | Overheat, short circuit, over current, and parameter lock and so on | ||
Environment | Ambient Temperature | -10 to 40 (non-freezing) | |
Ambient Humidity | Max. 95%(non-condensing) | ||
Altitude | Lower than 1000m | ||
Vibration | Max. 0.5G | ||
Structure | Cooling Mode | Forced air cooling | |
Protective Structure | IP20 | ||
Installation | Mode | Wall Mounted |