Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Input Rated Voltage | Single 220V | |
Output frequency,Voltage | 0.1Hz~400Hz ,0~230V | |
Capacity (kW) | 0.2 ~1.5kW | |
Key parts | Microchip MCU & DSP dual core calculation chip | |
Fairchild IGBT | ||
Delta Fan | ||
Certification | CE,ISO9001/14001,OHSAS 18001 | |
Control Mode | V/F Control,standard RS-485 communication | |
Output frequency resolution | 0.1Hz | |
Torque characteristic | There is torque compensation,slip compensation and at 3Hz the activating torque can reach above | |
Tolerance of overload | 150% of the rated output current, 60 sec. | |
Acceleration/deceleration time | 0.1~600 sec.(can have independent settings respectively) | |
V/F curve | Setting 6 fixed curves + any curves | |
Action position standard of avoiding losing speed | Setting with the percentage of rated current,20~200% | |
Frequency setting signal | Panel operation | Setting by buttons or V.R |
External signal | AVI/ACI setting,UP/DOWN setting,communication setting,pulse input setting | |
Signal of runsetting | Panel operation | Setting by RUN,STOP buttons |
External signal | M0,M1,M2 and M3 form run of various run modes; RS-485 communication port | |
Multifunction input signal | Selection of section command 0~15,FWD/REV inching motion command, acceleration/deceleration prohibition command,swiching command of first and second acceleration/deceleration,selection of counter,program run,external B.B.(NC,NO),pulse input,two kinds of 3-line wiring modes,output prohibition | |
Multifunction input signal | During run,run frequency arrival,setting frequency arrival,counter arrival,zero speed,abnormal displays in B.B,program run command,FWD/REV running direction command | |
Advantage and functions | 1.Mini Size | |
2.Economy and Competitive cost | ||
3.Adopt MCU & DSP dual core calculation chip, fast CPU calculation speed | ||
4.Great performance: auto torque compensation, auto slip detection compensation, low noise, high overload performance. | ||
5.Intelligent wobble frequency, could be applied in the occasions that required traverse or winding, such textile and fiber chemical etc. | ||
6.Built-in PLC, available to preset 16 sections of running program. | ||
Protective functions | Over voltage,over current,low voltage,limit of over load,electronic thermoelectric station,overheating,self-testing,grounding protection,abnormal contact | |
Cooling mode | Natural cooling/forced cooling | |
Environment | Application site | Height below 1000m,indoor,(free of corrosive gas,liquid and dust filth |
Ambient temperature | -10°C~40°C(no dewing and no freezing) | |
Storage temperature | -20°C~60°C | |
Hunidity | Below 90RH%(no dewing) | |
Vibration | Below 20Hz9.80665m/s²(1G) 20~50Hz 5.88m/s²(0.6G) |