Customization: | Available |
---|---|
Application: | Three Phase Transducer, General Transducer, Single-phase Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 125/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Built in PID contorl
V/F control
0.1~400Hz
Control up to 4 pumps for constant pressure water supply
Target market of S2100 E series Inverter
1.Central air conditioning and water supply by circulatory High-rise buildings, residential areas,
business units of life, HVAC, fire water supply system
2.Industrial and mining production water, such as cooling water, industrial water supply system, Boiler
3.Constant press oil system such as oil pipelines, oil depots, oil pumping stations and oil port
4.Drinking water plant, water booster pump station, water pumping station
5.Water treatment plants, sewage, waste water, industrial water treatment
6.The irrigation and drainage systems in large squares, green parks and farms
Why choose machtric frequency inverter?
1.Easy operating system.--- easy but effective software ,gentle touch achieve.
2.Stable performance--- best famous company ensure the quality all the time.
3.Excellent after sales service--- never leave you along.
4.Fast delivery --- safety delivery ,we look after it all the time.
We looking forward to cooperate with you !
Trust Alice can gave you more information abot product.
Items |
S2100 E |
|
Power Supply |
Rated voltage, Frequency |
Single phase/Three phase 220V 50/60Hz Single-phase 220V 50/60Hz |
Voltage Range |
380V:330V~440V; 220V:170V~240V |
|
Output |
Voltage Range |
380V:0~380V; 220V:0~220V |
Frequency Range |
0.10`400.00Hz |
|
Control method |
V/F control, Space vector control. |
|
Indication |
Operating status/Alarm definition/interactive guidance: e.g., frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. |
|
Control Specifications |
Output Frequency Range |
0.10Hz~400.00Hz |
Frequency Setting Resolution |
Digital input:0.01Hz, analog input:0.1% of maximum output frequency |
|
Output Frequency Accuracy |
0.01Hz |
|
V/F Control |
Setting V/F curve to satisfy various load requirements |
|
Torque Control |
Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque |
|
Multifunctional Input Terminal |
Eight multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions |
|
Multifunctional Output Terminal |
3 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings |
|
Acceleration/deceleration time Setting |
0~-6000s acceleration/deceleration time can be set individually |
|
Other Functions |
PID Control |
Built-in PID control |
RS485 |
Standard RS485 communication function(MODBUS) |
|
Frequency Setting |
Analog input:0 to 10V,,0 to 20mA can be selected; Digital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN |
|
Multi-speed |
Eight multifunction input terminals, 15section speed can be set |
|
Automatic voltage regulation |
Automatic voltage regulation function can be selected |
|
Counter |
Built -in 2group of counters |
|
Protection/ Warning Function |
Overload |
150%,60 second(Constant torque);120%.60 second (variable torque) |
Over Voltage |
Over voltage protection can be set |
|
Under Voltage |
Under voltage protection can be set |
|
Other Protections |
Overheat, short circuit, over current, and parameter lock and so on |
|
Environment |
Ambient Temperature |
-10°C to 40°C(non-freezing) |
Ambient Humidity |
Max.95%(non-condensing) |
|
Altitude |
Lower than 1000m |
|
Vibration |
Max. 0.5G |
|
Structure |
Cooling Mode |
Forced air cooling |
Protective Structure |
IP20 |
|
Installation |
Mode |
Below 90KW:Wall Mounted; 110~200KW:Wall Mounted or in Cabinet; Above 220KW:in Cabinet |