Customization: | Available |
---|---|
Application: | Three Phase Transducer, General Transducer, Single-phase Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Specifications:
Items | S800E | ||
Power | Rated voltage, Frequency | ||
Supply | One-phase/Three-phase AC 220V 50/60Hz | ||
Voltage Range | |||
220V: 170~240V | |||
Output | Voltage Range | 220V: 0~220V | |
Frequency Range | 0.10~400.00Hz | ||
Control method | V/F control, Space vector control. | ||
Indication |
Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/ current, DC bus voltage, the temperature and so on. |
||
Control SpeciAlations | Output Frequency | 0.10Hz~400.00Hz | |
Range | |||
Frequency Setting | Digital input: 0.01Hz, analog input: 0.1% of | ||
Resolution | maximum output frequency | ||
Output Frequency | 0.01Hz | ||
Accuracy | |||
V/F Control | Setting V/F curve to satisfy various load | ||
Requirements. | |||
Torque | Auto increase: auto raise torque by loading | ||
Control | Condition; Manual increase: enable to set | ||
0.0~20.0% of raising torque. | |||
Multifunctional | Four multi-function input terminals, realizing | ||
Input Terminal |
functions including fifteen section speed control, Program running, four section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions |
||
Multifunctional | 1 multi-function output terminals for displaying | ||
Output Terminal | of running, zero speed, counter, external | ||
abnormity, program operation and other | |||
Information and warnings. | |||
Acceleration/ deceleration Time Setting |
0~999.9s acceleration/deceleration time can be set individually. |
||
Other functions | PID Control | Built-in PID control | |
RS485 | Standard RS485 communication function(MODBUS) | ||
Frequency Setting | Analog input: 0 to 10 V, 0 to 20mA can be | ||
selected; | |||
Digital input:Input using the setting dial of the | |||
operation panel or RS485 or UP/DOWN. | |||
Note:AVI terminals can be used to select an | |||
analog voltage input(AV) and analog current | |||
input(AI) through the switch J2. | |||
Note: AVI terminals can be used to select an | |||
Analog voltage input (AV) and analog current | |||
Input(AI) through the switch J2. | |||
Multi-speed | Four multifunction input terminals, 15 section | ||
speed can be set | |||
Automatic | |||
voltage |
Model | Input | Power | Capacity | Current | Load | Motor |
Output | (KVA) | Output | Capacity | Equipped | ||
(KW) | (A) | (60s)(A) | (KW) | |||
S800-2T0.4GE | 1PH/3PH | 0.4 | 1 | 2.5 | 3.75 | 0.4 |
S800-2T0.75GE | 220V- | 0.75 | 2 | 5 | 7.5 | 0.75 |
S800-2T1.5GE | 50/60HZ | 1.5 | 2.8 | 7 | 10.5 | 1.5 |