Customization: | Available |
---|---|
Application: | Electric Razor |
Nature of Source Flow: | Active Inverter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Items |
S2100 E |
|
Power Supply |
Rated voltage, Frequency |
Single phase/Three phase 220V 50/60Hz Single-phase 220V 50/60Hz |
Voltage Range |
380V:330V~440V; 220V:170V~240V |
|
Output |
Voltage Range |
380V:0~380V; 220V:0~220V |
Frequency Range |
0.10`400.00Hz |
|
Control method |
V/F control, Space vector control. |
|
Indication |
Operating status/Alarm definition/interactive guidance: e.g., frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. |
|
Control Specifications |
Output Frequency Range |
0.10Hz~400.00Hz |
Frequency Setting Resolution |
Digital input:0.01Hz, analog input:0.1% of maximum output frequency |
|
Output Frequency Accuracy |
0.01Hz |
|
V/F Control |
Setting V/F curve to satisfy various load requirements |
|
Torque Control |
Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque |
|
Multifunctional Input Terminal |
Eight multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions |
|
Multifunctional Output Terminal |
3 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings |
|
Acceleration/deceleration time Setting |
0~-6000s acceleration/deceleration time can be set individually |
|
Other Functions |
PID Control |
Built-in PID control |
RS485 |
Standard RS485 communication function(MODBUS) |
|
Frequency Setting |
Analog input:0 to 10V,,0 to 20mA can be selected; Digital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN |
|
Multi-speed |
Eight multifunction input terminals, 15section speed can be set |
|
Automatic voltage regulation |
Automatic voltage regulation function can be selected |
|
Counter |
Built –in 2group of counters |
|
Protection/ Warning Function |
Overload |
150%,60 second(Constant torque);120%.60 second (variable torque) |
Over Voltage |
Over voltage protection can be set |
|
Under Voltage |
Under voltage protection can be set |
|
Other Protections |
Overheat, short circuit, over current, and parameter lock and so on |
|
Environment |
Ambient Temperature |
-10°C to 40°C(non-freezing) |
Ambient Humidity |
Max.95%(non-condensing) |
|
Altitude |
Lower than 1000m |
|
Vibration |
Max. 0.5G |
|
Structure |
Cooling Mode |
Forced air cooling |
Protective Structure |
IP20 |
|
Installation |
Mode |
Below 90KW:Wall Mounted; 110~200KW:Wall Mounted or in Cabinet; Above 220KW:in Cabinet |