| Customization: | Available |
|---|---|
| Application: | High-performance Transducer, Three Phase Transducer, General Transducer |
| Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Items | S900GS |
||
| Power Supply |
Rated voltage, Frequency | Single phase/Three phase 220V 50/60Hz | |
| Voltage Range | 220V:170V~240V 380V:330~440V | ||
| Output | Voltage Range | 220V:0~220V 380V:0~380V | |
| Frequency Range | 0.10~400.00Hz | ||
| Control method | V/F control, Space vector control. | ||
| Indication | Operating status/Alarm definition/interactive guidance: eg , frequency setting, the output frequency/current, DC bus voltage, the temperature and so on. | ||
| Control Specifications | Output Frequency Range | 0.10Hz~400.00Hz | |
| Frequency Setting Resolution | Digital input:0.01Hz, analog input:0.1% of maximum output frequency | ||
| Output Frequency Accuracy | 0.01Hz | ||
| V/F Control | Setting V/F curve to satisfy various load requirements | ||
| Torque Control | Auto increase: auto raise torque by loading condition; manual increase; enable to set0.0~20.0% of raising torque | ||
| Multifunctional lnput Terminal |
Six multi-function input terminals, realizing functions including fifteen section speed control, program running, four-section acceleration/deceleration speed switch, UP/DOWN function and emergency stop and other functions | ||
| Multifunctional Output Terminal |
2 multi-function output terminals for displaying of running, zero speed, counter, external abnormity, program operation and other information and warnings | ||
| Acceleration/deceleration Time Setting | 0~-999.9s acceleration/deceleration time can be set individually | ||
| PID Control | Built-in PID control | ||
| RS485 | Standard RS485 communication function(MODBUS) | ||
| Frequency Setting | Analog input:0 to 10V,,0 to 20mA can be selected; Dig ital input: Input using the setting dial of the operation panel or RS485 or UP/DOWN |
||
| Multi-speed | Six multifunction input terminals, 15section speed can be set | ||
| Automatic voltage regulation | Automatic voltage regulation function can be selected | ||
| Counter | Built -in 2group of counters | ||
| Protection/ Warning Function | Overload | 150%,60 second(Constant torque) | |
| Over Voltage | Over voltage protection can be set | ||
| Under Voltage | Under voltage protection can be set | ||
| Other Protections | Overheat, short circuit, over current, and parameter lock and so on | ||
| Environment | Ambient Temperature | -10ºC to 40ºC(non-freezing) | |
| Ambient Humidity | Max.95%(non-condensing) | ||
| Altitude | Lower than 1000m | ||
| Vibration | Max. 0.5G | ||
| Structure | Cooling Mode | Forced air cooling | |
| Protective Structure | IP20 | ||
| Installation | Mode | Wall Mounted | |