Customization: | Available |
---|---|
Application: | High-performance Transducer |
Output Type: | Single/Three Phases |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Input Voltage Level | 220V | |||||
Model S8000-2s*** | 0.2G | 0.4G | 0.75G | 1.5G | ||
Applicable Motor Power(kw) | 0.2 | 0.4 | 0.75 | 1.5 | ||
Rated output capacity(Kva) | 0.6 | 1.0 | 1.6 | 2.9 | ||
Rated output current(A) | 1.6 | 2.5 | 4.2 | 7.0 | ||
Maximum output voltage(v) | SINGLE-PHASE CORRESPONDING INPUT VOLTAGE | |||||
Range of output frequency(Hz) | 1.0~400 Hz | |||||
Rated input current(A) | 4.9/2.4 | 6.5/3.0 | 9.7/5.1 | 15.7/9 | ||
Admissible variation range | Single-phase power supply 200-240V 50/60Hz | |||||
of input voltage | ||||||
Variation range of power | +-5% | |||||
supply frequency | ||||||
Control mode | V/F& SVPWM spatial vector modulation | |||||
(carrier 2kHz-12kHz) | ||||||
Resolution of output frequency | 0.1 Hz | |||||
Torque characteristic | Torque and speed drop compensation function. | |||||
trigger torque can be up to 150% in 3 Hz | ||||||
Overload toleration | 60 seconds under 150%of Rated output current | |||||
Accelerating and decelerating time | 0.1~600seconds(can be set independently) | |||||
V/F curve | Randam V/F curve setting | |||||
Action adjustment to avoid losing speed | Set by percent of Rated current, 20%~200% | |||||
Protective Function | Over-voltage, over-current, low-voltage, overl | |||||
oad limits, electronic thermocouple, overheat, | ||||||
self-check, ground protection, abnormal port | ||||||
Type of Cooling | Air-blast cooling | |||||
Using location | Lower than 1000m, indoor(keep from corrosive | |||||
gases, liquids and dust) | ||||||
Environment temperature | -10~40(no dewing and icing) | |||||
Storage temperature | -20~60 | |||||
Humidity | Below 90%RH(no dewing) | |||||
Vibration | 9.80665m/s2 below 20Hz(1G) 5.88m/s2 below | |||||
20~50Hz(0.6G) |