Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Triple |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item |
S3800E |
|
Control mode |
V/F control | |
Sensorless flux vector control (VC) | ||
Cloed-loop vector control(CVC) | ||
Maximum frequency |
Vextor control :0~320Hz | |
V/F control :0~3200Hz | ||
Input frequency esolution |
Dgital setting :0.01Hz | |
Analog setting :0.025% of maximum frequency | ||
Startup torque |
G type :0.5Hz/150%; 0 Hz/ 180%(CVC) P type :0.5Hz/100% |
|
Speed range |
1:100(VC) 1:1000(CVC) |
|
Speed stability accuracy | ±0.2%(VC) ± 0.02%(CVC) |
|
Torque control accuracy | ±5%(CVC) | |
Overload capacity | G type : 60s for 150% of the rated current, 3s for 180% of the rated current P type : 60s for 120% of the rated current, 3s for 150% of the rated curren |
|
Torque boost | Auto boost Customized boost 0.1%-30.0% |
|
V/F curve | Multi-point curve N-power V/F curve (1.2 power ,1.4 power,1.6 power,1.8power,square ) |
|
V/F separation | Two types :complete separation ; half separation |
|
Ramp mode | Straight-line ramp S-curve ramp Four groups of acceleration /deceleration time with the range of 0.0.-6500s |
|
DC braking | DC braking frequency :0.00HZ to maximun frequency Braking time :0.0~100.0s Braking action current value :0.0%- 100.0% |
|
JOG control | JOG frequency range :0.00~ 50.00HZ JOG acceleration /deceleration time :0.0~ 6500.0s |
|
Onboard multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of terminal states | |
Onboard PID | It realizes process-controlled closed loop control system easily | |
Auto voltage Regulation (AVR) |
It can keep constant output voltage automatically when the mains voltage changes. |
|
Overvoltage /Overcurrent stall control | The current and voltage are limited automatically during the running process so as to avoid frequenct tripping due to overvoltage /over current | |
Torque limit and control | It can limit torque automatically and prevent frequent over current tripping during the running process .Torque control can be implemented in the CVC mode | |
Support for the multiple PG card | Support for rotating transformer PD card , differential input PG card, resolver PG card and OC input PG card | |
Power dip ride through | Reduction so that the AC drive can continue to run for a short time | |
Rapid current limit | It helps to avoid frequent over current faults of the AC drive | |
High performance | Control of asynchronous motor and synchronous motor are implemented through the high -performance current vector control technology . | |
Timing control | Time range : 0.0~ 6500.0 mintes |
|
Communication Methods | MODBUS -RTU , PROFIBUS -DP, CAN | |
Protection mode | Motor short -circuit detection at power -on , input/output phase loss protection ,over current protection, overvoltage protection, under voltage protection , overheat protection and overload protection | |
Installtion Location | Indoor , free from direct sunlight , dust , corrosive gas, combustible gas, oil smol, vapour , drip or salt | |
Altitude | Lower than 1000m | |
Ambient temperature | -10ºC40ºCde-rated if the ambient temperature is between 40ºC and 50ºC | |
Storage temperture | -20ºC~60ºC |